ONLINE SERVICES

CONDITIONS OF APPROVAL FOR tr31632

Online Services

Results for tr31632 as of 6/3/2026 7:59:47 PM

015 - BS-Grade
UNKNOWN
Grade-MAP* - NO GRDG & SUBDIVIDINGStatus
IF MASS GRADING IS PROPOSED - UNDER A PREVIOUSLY APPROVED SUBDIVISION, AT THE SAME TIME THAT APPLICATION FOR FURTHER SUBDIVISION FOR THAT PARCEL IS BEING MADE, AN EXCEPTION TO ORDINANCE 460 SECTION 4.4.B IS REQUIRED. OBTAIN THE EXCEPTION FROM THE PLANNING DIRECTOR.
015 - BS-Grade
UNKNOWN
Grade-MAP-G1.2 OBEY ALL GDG REGSStatus
All grading shall conform to the California Building Code, Ordinance 457, and all other relevant laws, rules and regulations governing grading in Riverside County and prior to commencing any grading which includes 50 or more cubic yards, the applicant shall obtain a grading permit from the Building & Safety Department.
015 - BS-Grade
UNKNOWN
Grade-MAP-G1.3 DISTURBS NEED G/PMTStatus
Ordinance 457 requires a grading permit prior to clearing , grubbing or any top soil disturbances related to construction grading.
015 - BS-Grade
UNKNOWN
Grade-MAP-G1.6 DUST CONTROLStatus
All necessary measures to control dust shall be implemented by the developer during grading.
015 - BS-Grade
UNKNOWN
Grade-MAP-G2.10 SLOPE SETBACKSStatus
Observe slope setbacks from buildings and property lines per the California Building Code - as amended by Ordinance 457.
015 - BS-Grade
UNKNOWN
Grade-MAP-G2.5 2:1 MAX SLOPE RATIOStatus
Grade slopes shall be limited to a maximum steepness ratio of 2:1 (horizontal to vertical) unless otherwise approved.
015 - BS-Grade
UNKNOWN
Grade-MAP-G2.8MINIMUM DRNAGE GRADStatus
Minimum drainage grade shall be 1% except on portland cement concrete where 0.35% shall be the minimum.
015 - BS-Grade
UNKNOWN
Grade-MAP-GIN INTRODUCTIONStatus
Improvement such as grading, filling, over excavation and recompaction, and base or paving which require a grading permit are subject to the included Building and Safety Grading Division conditions of approval.
015 - BS-Grade
UNKNOWN
Grade-SP -COMPLY W LANDUSEStatus
All subsequent subdivisions and specific land uses related to SP 293 shall comply with the recommendations of this Specific Plan and all its conditions of approval and shall reference themselves to it.
015 - BS-Grade
UNKNOWN
Grade-SP -CONFORMANCE W GEO/SOILSStatus
All grading shall be done in conformance with the recommendations of the included geotechnical/soils reports.
015 - BS-Grade
UNKNOWN
Grade-SP -DIFFERENCES IN SPStatus
Anything to the contrary, proposed by SPECIFIC PLAN NO. 293 shall not supersede the following. All grading shall conform to the Uniform Building Code, County General Plan, Ordinance 457 and all other relevant laws, rules and regulations governing grading in Riverside County.
015 - BS-Grade
UNKNOWN
Grade-SP -EROSION AND RAINY SEA CONStatus
Graded but undeveloped land shall provide, in addition to erosion control planting, any drainage facilities deemed necessary to control or prevent erosion. Additional erosion protection may be required during the rainy season from October 15 to April 15.
015 - BS-Grade
UNKNOWN
Grade-SP -GRAD W/SLOPES GREATER 25%Status
Grading in areas which have natural slopes of 25% or steeper will not be permitted without Planning Department approval.
015 - BS-Grade
UNKNOWN
Grade-SP -DEVELOPMENT STANDARDSStatus
Prior to an project approval the development standards of Specific Plan No. 293 shall be reviewed and complied with.
015 - BS-Grade
UNKNOWN
Grade-SP -GNATCATCHER PR GRADINGStatus
Prior to the issuance of any grading permit or recordation of the final map, the applicant shall obtain written approval from the United States Fish and Wildlife Service to "take" habitat occupied by the California Gnatcatcher (Polioptila californica californica). Said approval shall be obtained through the initiation of a consultation with the United States fish and Wildlife Service pursuant to Section 7 of the Endangered Species Act of 1973; approval by the Secretary of the Interior of a 10(a) Permit pursuant to Section 10 of the Endangered Species Act of 1973; or participation in the Natural Community Conservation Planning program established by the State of California.
015 - BS-Grade
UNKNOWN
Grade-SP -REQUIREMENTS OF B&SStatus
The subdivider shall comply with the requirements set forth in the Department of Building and Safety: Grading Section's transmittal dated 3/28/95, a copy of which is attached.
015 - BS-Grade
UNKNOWN
Grade-SP -CERTIFICATION AFFECT GRStatus
Prior to issuance of a grading permit, all certifications affecting grading shall have written clearances. This includes but is not limited to additional Environmental Assessments, Erosion Control plans, additional geotechnical and soils reports, Departmental clearances and the amount being graded. This applies as these are requirements of the specific plan, EIR or a condition of approval.
015 - BS-Grade
UNKNOWN
Grade-SP -DRAIN FAC & TERR CONFORMStatus
Provide drainage facilities and terracing in conformance with Section 7012 of the Uniform Building Code.
015 - BS-Grade
UNKNOWN
Grade-SP -DRAIN FAC FOR 100 YR FLStatus
All drainage facilities shall be designed to accommodate 100 year storm flows or as approved by the Riverside County Flood Control District.
015 - BS-Grade
UNKNOWN
Grade-SP -DRAINAGE GRAD MINIMUMStatus
Minimum drainage grade shall be 1% except on portland cement concrete where 0.35% shall be the minimum.
015 - BS-Grade
UNKNOWN
Grade-SP -DUST CONTROLStatus
During the actual grading, all necessary measures to control dust shall be implemented by the developer.
015 - BS-Grade
UNKNOWN
Grade-SP -GRAD PERMIT PRIOR TO CONStatus
Prior to issuance of any building permit, the property owner shall obtain a grading permit and approval to construct from the Building and Safety Department.
015 - BS-Grade
UNKNOWN
Grade-SP -GRADING IN EXCESS 199CYStatus
Grading in excess of 199 cubic yards will require performance security to be posted with the Building and Safety department.
015 - BS-Grade
UNKNOWN
Grade-SP -IMPORT/EXPORT GRAD PLANStatus
In instances where a grading plan involves import or export, prior to obtaining a grading permit, the applicant shall have obtained approval for the import/export location from the Building and Safety department.
015 - BS-Grade
UNKNOWN
Grade-SP -LANDSCAPE SIGN & BONDEDStatus
Landscape plans are to be signed and bonded per the requirements of Ordinance 457, see form 284-47.
015 - BS-Grade
UNKNOWN
Grade-SP -MASS GRADINGStatus
If mass grading of the entire Specific Plan site is proposed, UNDER A SUBDIVISION OR LAND USE CASE ALREADY APPROVED FOR THIS SPECIFIC PLAN, at the same time that application for further subdivision of its parcels is being made, an exception to Ordinance 460, Section 4.4b, shall be obtained from the Planning Director prior to issuance of the mass grading permit (Ordinance 460, Section 3.1). THIS EXCEPTION WILL NOT APPLY TO ANY CASE HAVING ONLY AN APPROVED SPECIFIC PLAN.
015 - BS-Grade
UNKNOWN
Grade-SP -NOT LETTER OFFSITE GRADStatus
A notarized letter of permission, from the affected property owners, is required for any proposed off-site grading.
015 - BS-Grade
UNKNOWN
Grade-SP -NPDES GENERAL PERMITStatus
This project will distrub five or more acres or is part of a larger project that will disturb five or more acres and will require a National Pollutant Discharge Elimination System (NPDES) Construction General Permit from the state Water Resources control Board. Clearance for grading shall not be given until either the district or the Department of Building and Safety has determined that the project has complied with the current County requirements for the regarding the NPDES Construction General Permit.
015 - BS-Grade
UNKNOWN
Grade-SP -NPDES NOTICEStatus
Notice: EFFECTIVE OCTOBER 1, 1992 OWNER OPERATORS OF CONSTRUCTION PROJECTS ARE REQUIRED TO COMPLY WITH THE NATIONAL POLLUTION DISCHARGE ELIMINATION SYSTEM (NPDES) CONSTRUCTION PERMIT FROM THE STATE WATER RESOURCE CONTROL BOARD (SWRCB). THE CONSTRUCTION PERMIT REQUIREMNT APPLIES TO CONSTRUCTION SITES OF FIVE ACRES AND LARGER OR SITES OF LESS THAN FIVE ACRES IF THE CONSTRUCTION ACTIVITY IS PART OF A LARGER COMMON PLAN OF DEVELOPMENT OR SALE. THE OWNER OPERATOR MAY OBTAIN COMPLIANCE BY SUBMITTING A NOTICE OF INTENT (NOI) AND MONITORING PLAN FOR THE CONSTRUCTION SITE. FOR ADDITIONAL INFORMATION AND TO OBTAIN A COPY OF THE NPDES STATE CONSTRUCTION PERMIT CONTACT THE SWRCB AT (916) 657-1146.
015 - BS-Grade
UNKNOWN
Grade-SP -OFFSITE CONSTRUCTIONStatus
A recorded easement is required for any proposed off-site construction.
015 - BS-Grade
UNKNOWN
Grade-SP -PREGRADE MEETINGSStatus
Any pregrade meetings shall include a Building and Safety Department Grading Division representative.
015 - BS-Grade
UNKNOWN
Grade-SP -PRIOR TO OVER 50CY GRADStatus
Prior to commencing any grading in excess of 50 cubic yards, the applicant shall obtain a grading permit and approval to construct from the Building and Safety department.
015 - BS-Grade
UNKNOWN
Grade-SP -SLOPE SETBACKSStatus
Observe slope setbacks per Section 2907, figure 29-1 Section 7011, and figure 70-1 of the Uniform Building Code.
015 - BS-Grade
UNKNOWN
Grade-SP -SLOPES PLAND AND IRRIGATEStatus
Plant and irrigate all slopes greater than or equal to 3' in vertical height with grass or ground cover. Slopes that exceed 15' in vertical height are to be provided with shrubs and/or trees per county ordiance 457, see form 284-47.
015 - BS-Grade
UNKNOWN
Grade-SP -STEPHENS KANGAROO RATStatus
No permits allowing grading, construction, or surface alterations, shall be issued unless a request for an allocation of take authorizing take of the Stephens' Kangaroo Rat has been approved by the Department of Building and Safety. Prior to the issuance of a grading permit, building permit for the construction of a primary structure, a mobilehome site preparation permit, or mobilehome installation jpermit, whichever comes first: a. A Section 10(a) Permit issued pursuant to the provisions of the Federal Endangered Species Act of 1073 and an Agency Agreement State Endangered Species Act which authorize take of the Stephens' Kangaroo Rat must be in effect. b. A report, prepared by a biologist permitted by the U.S. Fish and Wildlife Service to trap the Stephens' Kangaroo Rat for scientific purposes, documenting the amount and quality of occupied Stephens' Kangaroo Rat habitat subject to disturbance or destruction must have been submitted to the Department of Building and Safety for review and approval. In addition, a request for an allocation of take authorizing take of the Stephens' Kangaroo Rat must have been submitted to and approved by the Department of Building and Safety.
015 - BS-Grade
UNKNOWN
Grade-SP -STEPHENS KANGAROO RATStatus
Prior to the issuance of a grading or building permit, the applicant shall comply with the provisions of Ordinance No. 663 by paying the appropriate fee set forth in that ordinance. Shoudl Ordinance No. 663 be superseded by the provisions of a Long Term Habitat Conservation Plan for the Stephens' Kangaroo Rat prior to the payment of the aforementioned fee, the applicant shall pay the fee required by the Long Term Habitat Conservation Plan for the Stephens' Kangaroo Rat as implemented by County ordinance or resolution.
015 - BS-Plan Check
UNKNOWN
Plan Check-BP - BMR043839 FINALEDStatus
NOT FINAL ON THE GARAGE UNTIL BMR043839 IS FINALED OR BOTH TOGETHER. GARAGE NOT ALLOWED IN RA ZONE WITHOUT A MAIN BUILDING. BOTH CAN BE FINALED TOGETHER.
015 - E Health
UNKNOWN
EOT3- ECP COMMENTSStatus
The Environmental Cleanup Program (ECP) has reviewed the Limited Phase II environmental site assessment report submitted for this project. Based on the information provided in the reports, the results of the sampling conducted at the site and other documents, staff and with the provision that the information was accurate and representative of site conditions, the ECP concludes no further environmental assessment is required for this project. We also concur with Hillman Consulting that an environmental professional be present during grading activities to observe the soil for any discoloration or the possibility of evidence of USTs. If previously unidentified contamination or the presence of a naturally occurring hazardous material is discovered at the site, assessment, investigation, and/or cleanup may be required. Contact Riverside County Environmental Health - Environmental Cleanup Programs at (951) 955-8980, for further information.
015 - E Health
UNKNOWN
SP - COMMENTS ON A2Status
The project is to be serviced water and sanitary sewer by Eastern Municipal Water District. Use of reclaimed water is to be encouraged fpr all greenbelt and landscaped areas.
015 - E Health
UNKNOWN
SP - COMMENTS ON A3Status
Eastern Municipal Water District (EMWD) will be providing the water and sanitary sewer facilities which will be servicing the Winchester Hills Specific Plan. EMWD will need again to specify in their "will-serve" letters for Amended No. 3 exactly which water reclamation facility willbe treating the flow(s) from the Winchester Hills development, i.e. Peris Valley, Sun City, Etc.
015 - E Health
UNKNOWN
SP -DEVELOPMENT STANDARDSStatus
Prior to any project approval the development standards of Specific Plan No. 293 shall be reviewed and complied with.
015 - Fire
UNKNOWN
MAP-#16-HYDRANT/SPACINGStatus
Schedule A fire protection approved standard fire hydrants, (6"x4"x2 1/2") located one at each street intersection and spaced no more than 330 feet apart in any direction, with no portion of any lot frontage more than 165 feet from a hydrant. Minimum fire flow shall be 1000 GPM for 2 hour duration at 20 PSI. Shall include perimeter streets at each intersection and spaced 660 feet apart.
015 - Fire
UNKNOWN
MAP-#50-BLUE DOT REFLECTORSStatus
Blue retroreflective pavement markers shall be mounted on private streets, public streets and driveways to indicate location of fire hydrants. Prior to installation, placement of markers must be approved by the Riverside County Fire Department.
015 - Fire
UNKNOWN
SP -DEVELOPMENT STANDARDSStatus
Prior to any project approval the development standards of Specific Plan No. 293 shall be reviewed and complied with.
015 - Flood
UNKNOWN
MAP ADP FEES -GENERAL INFOStatus
The northeast corner of the site is located within the bounds of the Salt Creek Channel, Winchester-North Hemet Area Drainage Plan (ADP) for which drainage fees have been established by the Board of Supervisors. Applicable ADP fees will be due (in accordance with the Rules and Regulations for Administration of Area Drainage Plans) prior to permits for this project. Although the current fee for this ADP is $131 per acre, the fee due will be based on the fee in effect at the time of payment. The fee is payable to the Flood Control District by cashier's check or money order only. The District will not accept personal or company checks.
015 - Flood
UNKNOWN
MAP BMP - ENERGY DISSIPATORStatus
Energy Dissipators, such as rip-rap, shall be installed at the outlet of a storm drain system that discharges runoff flows into a natural channel or an unmaintained facility. The dissipaters shall be designed to minimize the amount of erosion downstream of the storm drain outlet.
015 - Flood
UNKNOWN
MAP BMP - TRASH RACKSStatus
Trash Racks shall be installed at all inlet structures that collect runoff from open areas with potential for large, floatable debris.
015 - Flood
UNKNOWN
MAP CONST OUTLET TO SALT CREEKStatus
The developer shall construct all storm drain facilities required to protect the site from flooding per drainage plan for the Winchester Hills Specific Plan or the CFD storm drain facilities MDP if finally approved.
015 - Flood
UNKNOWN
MAP FEMA PANEL NOStatus
Tract 31632 is within the 100 year Zone A flood plain limits as delineated on Panel No. 060245-2125 of the Flood Insurance Rate Maps issued in conjunction with the National Flood Insurance Program administered by the Federal Emergency Management Agency (FEMA).
015 - Flood
UNKNOWN
MAP FLOOD HAZARD REPORTStatus
Tract 31632 is a proposal to subdivide 55.59-acres into residential lots in the Winchester area. The site is located on the northwest corner of Newport Road and Rice Road, Salt Creek bisects this tract. This tract is within the Winchester Hills Specific Plan (SP 293). The northern portion of the site is located within the 100 year Zone A floodplain limits for Salt Creek as delineated on Panel No. 060245-2125 of the Flood Insurance Rate Maps issued in conjunction with the National Flood Insurance Program administered by the Federal Emergency Management Agency (FEMA). The District is currently constructing Stage 6 of the Salt Creek Channel through this site. This site may be still subject to Salt Creek overflows until the existing undersized box culvert at Rice Road is removed as an impediment. This improvement will have to be made in order to clear up the floodplain for Salt Creek in its entirety. The removal of this culvert is not part of the Salt Creek Channel Stage 6 contract, nor is it part of the Specific Plan. The developer will be required to obtain a Conditional Letter of Map Revision (CLOMR) from FEMA prior to issuance of grading permits or recordation of the final map, unless the District has already revised the map. Alternatively, the Chief Engineer may approve grading once the construction of the District's Salt Creek Channel project is complete, the plans for the removal of the Rice Road obstruction are approved and bonded and the developer has submitted hydraulic studies showing that the 100-year flood plain is contained in the channel. The developer shall obtain a LOMR prior to final building inspections for lots impacted by the floodplain. A drainage area of approximately 100 acres is tributary to the site from the south. The tentative map does not show any means to address this. However, the storm drains proposed by this tract (31632) and Tract 31633 are also contained in the CFD storm drain facilities master drainage plan being finalized by Webb Engineering. This network of storm drains would be the functional equivalent to the system proposed in the drainage plan in the approved Winchester Hills SP 293. These proposed facilities would protect this site (Tract 31632) from offsite flows from the south. Tract 31632 has three options: 1. Wait for the offsite facilities to be constructed by others 2. Construct the offsite facilities itself or 3. Devise an alternate interim scheme of flood protection. Interim facilities would still need to be constructed to District standards and must be publicly maintained in order to be credited with providing for public health and safety. The applicant shall construct the approved MDP drainage facilities along this site and construct the necessary MDP facilities upstream of Newport Road that would provide adequate collection of tributary storm flows into the MDP facilities. This would require some offsite improvements that shall be addressed in the environmental assessment for this tract. Should this development desire to use the existing maintenance roads for Salt Creek Channel as a multi-purpose trail the developer shall identify a viable entity to hold harmless, defend and indemnify the District.
015 - Flood
UNKNOWN
MAP OWNER MAINT NOTICEStatus
The subdivider shall record sufficient documentation to advise purchasers of any lot within the subdivision that the owners of individual lots are responsible for the maintenance of the drainage facility within the drainage easements shown on the final map.
015 - Flood
UNKNOWN
MAP POST CONST BMPS FILTRATIONStatus
All proposed impervious areas shall be graded or constructed to drain to a filtration BMP or equally effective alternative. Filtration BMP's can be found in the attachment to Supplement A, "Selection of Design of Stormwater Quality Controls".
015 - Flood
UNKNOWN
XXM-10 YR CURB - 100 YR ROWStatus
The 10 year storm flow shall be contained within the curb and the 100 year storm flow shall be contained within the street right of way. When either of these criteria is exceeded, additional drainage facilities shall be installed. All lots shall be graded to drain to the adjacent street or an adequate outlet.
015 - Flood
UNKNOWN
XXM-100 YR SUMP OUTLETStatus
Drainage facilities outletting sump conditions shall be designed to convey the tributary 100 year storm flows. Additional emergency escape shall also be provided.
015 - Flood
UNKNOWN
XXM-COORDINATE DRAINAGE DESIStatus
Development of this property shall be coordinated with the development of adjacent properties to ensure that watercourses remain unobstructed and stormwaters are not diverted from one watershed to another. This may require the construction of temporary drainage facilities or offsite construction and grading.
015 - Flood
UNKNOWN
XXM-SUBMIT DRAINAGE EASE DOCStatus
A drainage easement shall be obtained from the affected property owners for the release of concentrated or diverted storm flows onto the adjacent property. A copy of the recorded drainage easement shall be submitted to the District for review and approval.
015 - Flood
UNKNOWN
SP -COMPLIANCE W/LETTERStatus
The subdivider shall comply with the requirements set forth by the Riverside County Flood Control District's letter dated 4/25/95, a copy of which is attached. (Amended by Staff prior to the Planning Commission hearing on 7/19/95.)
015 - Flood
UNKNOWN
SP -FLOODPLAIN AFFECTSStatus
A portion of the proposed project is in a floodplain and may affect "waters of the United States", "wetlands" or "jurisdictional streambeds", therefore, in accordance with the requirements of the National Flood Insurance Program and Related Regulations (44 CFR, Parts 59 through 73) and County Ordinance No. 458: a. A flood study consisting of HEC-2 calculations, cross sections, maps and other data should be prepared to the satisfaction of the Federal Emergency Management Agency (FEMA) and the District for the purpose of revising the effective Flood Insurance Rate Map of the project site. The submittal of the related Salt Creek Channel improvement plans and final District approval will not be given until a conditional Letter of Map Revision (CLOMR) has been received from FEMA. Salt Creek Channel construction bonds shall not be released until a final letter of Map Revision (LOMR) has been obtained from FEMA. The applicant shall be responsible for payment of all processing fees required by FEMA for the CLOMR and LOMR. FEMA submittals for a CLOMR shall be reviewed by the District on a fee for service basis as a special hydraulic study, and a minimum deposit of $3,000 will be required before processing is initiated. A flat fee of $2,000 shall be required prior to final Salt Creek Channel improvement plan approval to cover the cost of processing the LOMR. Payment of all District fees and deposits for processing of FEMA submittals shall be made directly to the District. Fees for processing FEMA submittals shall be in addition to regular District plan check fees.
015 - Flood
UNKNOWN
SP -DOWNSTREAM DRAINAGEStatus
The downstream drainage facilities necessary to drain this project shall be in place prior to issuance of any building permits or as approved by Riverside County Flood Control and Water Conservation District.
015 - Flood
UNKNOWN
SP -MAPPED FLOOD PLAINStatus
A mapped flood plain is impacted by this project, therefore, the applicant shall obtain a Section 1601/1603 Agreement from the California Department of Fish and Game and a Clean Water Act Section 404 Permit from the U.S. Army Corps of Engineers, or written correspondence from these agencies indicating the project is exempt from these requirements prior to recordation of the individual tracts which impact the mapped flood plain. A Clean Water Act Section 401 Water Quality Certification may be required from the local California Regional Water Quality Control Board prior to issuance of the Corps 404 permit.
015 - Flood
UNKNOWN
SP -NPDES REQUIREMENTStatus
This project will disturb more than five acres and will require a National Pollutant Discharge Elimination System (NPDES) permit from the State Water Resources Control Board. Clearance for any grading shall not be given until either the District or the Department of Building and Safety has determined that the project has been granted a permit or is shown to be exempt.
015 - Flood
UNKNOWN
SP -SALT CREEK WATERSHEDStatus
Prior to recordation of any subdivision map within the Salt Creek watershed, including financing map, the ultimate Salt Creek Channel through the project along with appropriate collection and outlet facilities must be constructed or a financing mechanism other than Salt Creek ADP to pay for its construction must be in place.
015 - General
UNKNOWN
MAP - PA 32 Park ConstructionStatus
Prior to the issuance of the 150th Building permit the community Park in Planning Area 32 designated as "196 OS" shall be constructed and fully operable.
015 - General
UNKNOWN
MAP - PA 32 Park PlanningStatus
Prior to the issuance of the 75th building permit the community park in Planning Area 32 designated as " 196 OS" detailed plans for the construction of the park shall be submitted for review and approval by the approriate agencies.
015 - General
UNKNOWN
SP - PARK DISTRICT APPROVALStatus
To Whom it May Concern, The purpose of this letter is to confirm that the County defers to the Valley-Wide Recreation and Park District with respect to the park-related conditions in the Winchester Hills specific plan (SP293). SP293 has been revised a number of times; the area that it covers has had a number of property owners; and several tentative tract maps have been approved under SP293 with different, sometimes conflicting, park conditions. Ultimately, implementation of the park conditions is overseen by Valley-Wide. Valley-Wide is the responsible agency for parks in the SP293 area and has expertise in the design and maintenance of parks and recreational facilities. For these reasons, to clear any park condition on any of the tentative tract maps approved under SP293, the County requires a clearance letter from Valley-Wide indicating that the intent of the condition has been met. Valley-Wide determines how the park conditions for SP293 and the implementing maps are best carried out and if those conditions have been satisfied. To be accepted by the County, a clearance letter from Valley-Wide should indicate how the specific-plan and implementing-map conditions have been addressed and state clearly that the conditions have been satisfied to the satisfaction of Valley Wide. Clarifying Valley-Wide's authority in this matter should help avoid confusion and miscommunication regarding park conditions on SP293 projects going forward. Thank you for your effort to help SP293 be a success for county residents. Sincerely, Matt Straite, Principal Planner
015 - Planning
UNKNOWN
BIO COMMENTSStatus
PDB# 2716 - General bio survey; prepared by Principe & Associates 2/2004; received 2/27/04. 55.59 acres of flat-lying topography which has been cleared for former residential and agricultural usage. About half the site contains only ruderal vegetation with scattered ornamental eucalyptus trees. The other half of the site is wheat field. No water occurs on the site. The lack of vernal pools and alkaline soil precludes habitat for Wright's trichocoronis, spreading navarretia, and CA Orcutt grass. No burrowing owls or potential burrows were observed. SKR fee is required.
015 - Planning
UNKNOWN
MAP - DESIGN GUIDELINESStatus
The project shall conform to Countywide Design Standards and Guidelines adopted January 13, 2004.
015 - Planning
UNKNOWN
MAP - FEES FOR REVIEWStatus
Any subsequent review/approvals required by the conditions of approval, including but not limited to grading or building plan review or review of any mitigation monitoring requirement, shall be reviewed on an hourly basis, or other appropriate fee, as listed in ounty Ordinance No. 671. Each submittal shall be accompanied with a letter clearly indicating which condition or conditions the submittal is intended to comply with.
015 - Planning
UNKNOWN
MAP - GEO NO. 1262Status
County Geologic Report (GEO) No. 1261 and 1262 consist of the same document and was submitted for Tract 31633 and Tract 31632 respectively. The report was prepared by EnGen Corporation and is entitled: "Geotechnical/Geological Engineering Study, Assessor's Parcel Numbers: 461-210-003, 461-210-004, 461-210-007, 461-200-002, 461-200-011, 461-200-013, 461-200-014, 461-200-016, SF 150 - Tracts 31632 and 31633, Rice Road and Olive Avenue, Winchester area of Riverside County, California", dated December 23, 2003. In addition, EnGen prepared the following documents, which are herein incorporated as a part of GEO No. 1261 and 1262: 1."Response to Review Comments, County Geologic Report No. 1261 & No. 1262 (Liquefaction), SF 150 - Tracts 31633 and 31632, Assessor's Parcel Numbers: 461-210-003, 461-210-004, 461-210-007, 461-200-002, 461-200-011, 461-200-013, 461-200-014, 461-200-016, Rice Road and Olive Avenue, Winchester area of Riverside County, California", dated May 31, 2004. 2."Response to Review Comments No. 2, County Geologic Report No. 1261 & No. 1262 (Liquefaction), SF 150 - Tracts 31633 and 31632, Assessor's Parcel Numbers: 461-210-003, 461-210-004, 461-210-007, 461-200-002, 461-200-011, 461-200-013, 461-200-014, 461-200-016, Rice Road and Olive Avenue, Winchester area of Riverside County, California", dated August 31, 2004. GEO No. 1261 & 1262 concluded: 1.Portions of the project site [Planning Area 30, extending to the area immediately south of Salt Creek (northernmost portion of PA 32)] were found to be potentially liquefiable. 2.Most portions of the site (Planning Area 33 and Tract 31633) were found to be non-liquefiable. 3.The intermingling of sediments carried by a meandering stream and those derived from a local source produced a highly heterogeneous package of interbedded coarse- and fine-grained soils. These complex depositional environments created the wide variety of grain sizes and soil densities encountered regionally and that directly influences liquefaction at each one of the sites. 4.At the specific sites considered in this study, EnGEN found conditions that would require removals of at least 5-feet. EnGEN did not find conditions that would warrant a blanket removal depth of 8-feet. Blanket removal to 8-feet is not necessary since there is no indication of potential for lateral spread. GEO No. 1261 & 1262 recommended: 1.Removal of 5 feet of alluvium to accomplish mitigation the potential of both liquefaction and hydrocollapse. 2.Use of post-tensioned slab-on-grade foundations for the zone immediately adjacent to the Salt Creek channel and the area north of Salt Creek. 3.The site conditions and report recommendations are to be re-evaluated and verified by the conditions encountered during grading. GEO No. 1262 and 1263 satisfy the requirement for a liquefaction study for Planning/CEQA purposes. GEO No. 1340 is hereby accepted for planning purposes.
015 - Planning
UNKNOWN
MAP - LANDSCAPE MAINTENANCEStatus
The land divider, or any successor-in-interest to the land divider, shall be responsible for maintenance and upkeep of all slopes, landscaped areas and irrigation systems within the land division until such time as those operations are the responsibility of the individual home owners, a homeowners association, or any other successor-in-interest.
015 - Planning
UNKNOWN
MAP - MAP ACT COMPLIANCEStatus
This land division shall comply with the State of California Subdivision Map Act and to all requirements of County Ordinance No. 460, Schedule A, unless modified by the conditions listed herein.
015 - Planning
UNKNOWN
MAP - NO OFFSITE SIGNAGEStatus
There shall be no offsite signage associated with this land division, except as otherwise provided by Ordinance No. 679.3 (Kiosk Program).
015 - Planning
UNKNOWN
MAP - NPDES COMPLIANCE (1)Status
Since the project will disturb one (1) acre or more, the land divider/permit holder shall comply with all of the applicable requirements of the National Pollution Discharge Elimination System (NPDES) and shall conform to NPDES Best Management Practices for Stormwater Pollution Prevention Plans during the life of this permit.
015 - Planning
UNKNOWN
MAP - OFFSITE SIGNS ORD 679.4Status
No offsite subdivision signs advertising this land ivision/development are permitted, other than those allowed under Ordinance No. 679.4. Violation of this condition of approval may result in no further permits of any type being issued for this subdivision until the unpermitted signage is removed.
015 - Planning
UNKNOWN
MAP - ORD 810 OPN SPACE FEEStatus
Prior to the issuance of either a certificate of occupancy or prior to building permit final inspection, the applicant shall comply with the provisions of Riverside County Ordinance No. 810, which requires payment of the appropriate fee set forth in the Ordinance. Riverside County Ordinance No. 810 has been established to set forth policies, regulations and fees related to the funding and acquisition of open space and habitat necessary to address the direct and cumulative environmental effects generated by new development projects described and defined in this Ordinance. The fee shall be paid for each residential unit to be constructed within this land division. In the event Riverside County Ordinance No. 810 is rescinded, this condition will no longer be applicable. However, should Riverside County Ordinance No. 810 be rescinded and superseded by a subsequent mitigation fee ordinance, payment of the appropriate fee set forth in that ordinance shall be required.
015 - Planning
UNKNOWN
MAP - ORD NO. 659 (DIF)Status
Prior to the issuance of either a certificate of occupancy or prior to building permit final inspection, the applicant shall comply with the provisions of Riverside County Ordinance No. 659, which requires the payment of the appropriate fee set forth in the Ordinance. Riverside County Ordinance No. 659 has been established to set forth policies, regulations and fees related to the funding and construction of facilities necessary to address the direct and cummulative environmental effects generated by new development projects described and defined in this Ordinance, and it establishes the authorized uses of the fees collected. The fee shall be paid for each residential unit to be constructed within this land division. In the event Riverside County Ordinance No. 659 is recinded, this condition will no longer be applicable. However, should Riverside County Ordinance No. 659 be rescinded and superseded by a subsequent mitigation fee ordinance, payment of the appropriate fee set forth in that ordinance shall be required.
015 - Planning
UNKNOWN
MAP - REQUIRED MINOR PLANSStatus
For each of the below listed items, a minor plot plan application shall be submitted and approved by the County Planning Department pursuant to Section 18.30.a. (1) of County Ordinance No. 348 (Plot Plans not subject to the California Environmental Quality Act and not subject to review by any governmental agency other than the Planning Department) along with the current fee. 1. Final Site Development Plan for each phase of development. 2. Model Home Complex Plan shall be filed and approved for each phase if models change between phases. A final site of development plot plan must be approved prior to approval, or concurrent with a Model Home Complex Plan. 3. Landscaping Plan for typical front yard/slopes/open space. These three plans may be applied for separately for the whole tract or for phases. 4. Landscaping plans totally in the road right-of-Way shall be submitted to the Transportation Department only. 5. Each phase shall have a separate wall and fencing plan. 6. Entry monument and gate entry plan. NOTE: The requirements of the above plot plans may be accomplished as one, or, any combination of multiple plot plans required by these conditions of approval. However, each requirement shall be cleared individually with the applicable plot plan condition of approval in the "PRIOR TO BUILDING PERMIT" (80 series) conditions.
015 - Planning
UNKNOWN
MAP - TRAIL MAINTENANCEStatus
The land divider, or the land divider's successor-in- interest, shall be responsible for the maintenance of any trail easement required under these conditions until such time as the maintenance is taken over by an appropriate maintenance district.
015 - Planning
UNKNOWN
MAP - VIABLE LANDSCAPINGStatus
All plant materials within landscaped common areas shall be maintained in a viable growth condition throughout the life of this permit. To ensure that this occurs, the Planning Department shall require inspections in accordance with the Department's Milestone 90 condition entitled "MAP - LNDSCP/IRRIG INSTALL INS." EOT1
015 - Planning
UNKNOWN
MAP FRONT YARD LANDSCAPINGStatus
This condition applies only to Schedule A-D tract maps. All front yards shall be provided with landscaping and automatic irrigation as defined by County Ordinance No. 348. Landscaping and Irrigation shall comply with the Riverside County Guide to California Friendly Landscaping, and Ordinance No. 859 (as adopted and any amendments thereto) provided that said ordinance has been amended to address residential tracts. EOT1
015 - Planning
UNKNOWN
MAP*- MAP ACT COMPLIANCEStatus
NOT FINAL ON THE GARAGE UNTIL BMR043839 IS FINALED OR BOTH TOGETHER. GARAGE NOT ALLOWED IN RA ZONE WITHOUT A MAIN BUILDING. BOTH CAN BE FINALED TOGETHER.
015 - Planning
UNKNOWN
MAP*- ORIGINAL APPROVAL DATEStatus
The Board of Supervisors approval date of the original tentative map occurred on ___. All determinations of whether the land division is eligible for an extension of time shall be based on this original approval date.
015 - Planning
UNKNOWN
SP -DIM OR DIS OF AG PRESStatus
Prior to or concurrent with the submittal of any subdivision map, or other development proposal for property within Planning Areas 30, 31, 32, 33, and 45b in SPECIFIC PLAN NO. 293, the applicant shall submit, to the Planning Department, an application for the diminishment or disestablishment of the agricultural preserve affecting the planning area(s) within which the proposed project is located, and where needed shall also submit a petition for the cancellation of the applicable land conservation contracts. (Amended by Planning Staff prior to the Planning Commission hearing on 9/13/95.)
015 - Planning
UNKNOWN
SP -DISES & DIMISN AG PRESStatus
Prior to or concurrent with the submittal of an application for the diminishment or disestablishment of the agricultural preserve for a planning area within SPECIFIC PLAN NO. 293, a change of zone application, proposing zoning necessary to implement the land uses set forth in the specific plan as an alternative to agricultural use of the planning area, shall be filed with the Planning Department. This change of zone must ultimately be heard and approved by the Planning Commission and Board of Supervisors.
015 - Planning
UNKNOWN
SP* - PROJ PA STANDARDSStatus
This implementing project is within Planning Areas 30, 32, and 33 of the SPECIFIC PLAN (Winchester Hills). Accordingly, this project is subject to these development standards: 1. All residential lots must be at least 6000 square feet. 2. The maximum number of dwelling units in this planning area is 186. 3. Entry monumentation is required at the intersection of Olive and Streets O and L and at Newport and Adams and at Rice and Street A. 4. Roadway landscaping is required along Rice, Newport and Olive Roads. 5. Recreational trails are located along Salt Creek, and Newport and Olive Roads. 6. This implementing map is conditioned to build a park at NW intersection of Rice and Patton prior to the 165th building permit. 7. Residential buildings must conform substantially to the design guidelines on pages IV-1 to IV-368 of the SPECIFIC PLAN. 8. Sidewalks along Olive and Newport Road shall be meandering, in substantial conformance to Figure IV-118 of the SPECIFIC PLAN.
015 - Planning
UNKNOWN
MAP - EXPIRATION DATEStatus
The conditionally approved TENTATIVE MAP shall expire three (3) years after the ounty of Riverside Board of Supervisors original approval date, unless extended as provided by County Ordinance No. 460. Action on a minor change and/or revised map request shall not extend the time limits of the originally approved TENTATIVE MAP. A Land Management System (LMS) hold shall be placed on the TENTATIVE MAP, and a LMS hold shall be placed on any subsequent minor change or revised map, which shall be set to take effect on the expiration date. The LMS hold effective date shall be extended in accordance with any permitted extensions of time. The LMS hold shall be downgraded to a LMS notice upon recordation of the the first phase of the TENTATIVE MAP. The LMS hold or notice shall remain in effect until the recordation of the final phase of the TENTATIVE MAP. If the TENTATIVE MAP expires before the recordation of the final phase the LMS hold or notice shall remain in effect and no further FINAL MAP recordation shall be permitted.
015 - Planning
UNKNOWN
SP - PASEO GRE P AREA 21Status
Paseo Greenbelt (Planning Area 21)- To be completed concurrently with adjacent development in Planning Area 21
015 - Planning
UNKNOWN
SP -ARCH STUDY PRIOR TOStatus
Prior to the preparation of Archaelogical Survey, the Archaelogist shall consult with the Pechanga Band of Luiseno Indians regarding the significance of archeological sites, and their proper mitigation. There shall be a tribal monitor present during the test excavation phase. Prior to excavations, there shall be an agreement in place for the return of sacred objects, religious items, or human remains to the tribe.
015 - Planning
UNKNOWN
SP -CEQA AMENDMENTStatus
An amendment to the California Environmental Quality Act (CEQA), codified as Public Resources Code Section 21081.6 required the preparation of a program to ensure that all mitigation measures are fully and completely implemented. The Environmental Impact Report prepared for SPECIFIC PLAN NO. 293, imposes certain mitigation measures on the project. Certain conditions of approval for SPECIFIC PLAN NO. 293 constitute self contained reporting/monitoring programs for certain mitigation measures. At the time of approval of subsequent development applications, further environmental reporting/monitoring programs will be established to ensure that all mitigation measures are appropriately implemented.
015 - Planning
UNKNOWN
SP -DESIGN PLANSStatus
Design plans for the common areas specifying the location and extent of landscaping and irrigation systems as specified in Riverside County Ordinance No. 348, Section 18.12, and Sections 19.300 through 19.304, and circulation (vehicular, pedestrian, equestrian and/or bicycle) shall be submitted during the review process for development applications, which incorporate common areas. Additionally, all proposed structures shall be shown on said plans.
015 - Planning
UNKNOWN
SP -DEVELOPMENT STANDARDSStatus
Prior to any project approval the development standards of Specific Plan No. 293 shall be reviewed and complied with.
015 - Planning
UNKNOWN
SP -FIRE STATION PAREA 42Status
Fire Station (Planning Area 42)- Site will be dedicated to the County during or prior to development within Planning Area 42
015 - Planning
UNKNOWN
SP -LOTS CREATEDStatus
Lots created by land divisions within SPECIFIC PLAN NO. 293 shall be in conformance with the development standards of the zone ultimately applied to the property, and all other applicable County standards.
015 - Planning
UNKNOWN
SP -OPEN SPACE PAREAS 59&49Status
Open Space (Planning Areas 59 & 49)- Deed transfer to public/private entity to occur at parcelization of any adjacent Planning Area within Phase IV
015 - Planning
UNKNOWN
SP -PASEO GRE P AREA 28Status
Paseo Greenbelt (Planning Area 28a)- To be completed concurrently with adjacent development in Planning Area 28)
015 - Planning
UNKNOWN
SP -PASEO GRE P AREA 33Status
Paseo Greenbelt (Planning Area 33)- To be completed concurrently with adjacent development in Planning Area 33
015 - Planning
UNKNOWN
SP -PASEO GRE P AREA 38Status
Paseo Greenbelt (Planning Area 38)- To be completed concurrently with adjacent development in Planning Area 38
015 - Planning
UNKNOWN
SP -PASEO GRE P AREA 7&15Status
Paseo Greenbelt (Planning Area 7 & 15- To be completed concurrently with adjacent development in Planning Area 7
015 - Planning
UNKNOWN
SP -PASEO GREEN P AREA 1&2Status
Paseo Greenbelt (Planning Area 7 & 15)- To be completed concurrently with retail/commercial development in Planning Area 1
015 - Planning
UNKNOWN
SP -PRIOR TO SUB MAPS OR APPRStatus
Prior to approval of any subdivision maps or approval of any plot plan or use permit, SPECIFIC PLAN NO. 293, COMPREHENSIVE GENERAL PLAN AMENDMENT NO. 336, AND CHANGE OF ZONE NO. 6013 shall be approved by the Board of Supervisors and shall be effective. (Amended by Planning Staff prior to the Planning Commission hearing on 9/13/95.)
015 - Planning
UNKNOWN
SP -SPECIAL STUDIES/REPORTStatus
The following special studies/reports shall accompany implementing development applications in the planning areas listed below: Study/Report Planning Area a. Detailed Preliminary Grading All Planning Areas Plans b. Liquefaction Report All Planning Areas c. Archaeological Survey 21, 22, 25, 26a, 26b, 27, 42 through 61 d. Biological Survey All Planning Areas e. Acoustical Study All Planning Areas f. Other (as determined by All Planning Areas subsequent environmental assessments)
015 - Planning
UNKNOWN
SP -HEMET UNIFIED SCHOOL MITStatus
Impacts to the Hemet Unified School District will be mitigated in accordance with California State law. All school sites shall meet the requirements of the district in terms of size, location, access, and absence from environmental constraint.
015 - Planning
UNKNOWN
SP -PARK PLANS P AREA 55Status
Prior to the issuance of any building permits within Planning Areas 50a, 50b, 51, 52, 53, 57, 58, 60, or 61, detailed park plans shall be submitted to and approved by the Planning Department and the Valley-Wide Recreation and Park District or other entity as set forth in Condition of Approval No. 3.11 for the park site identified as Planning Area 55. The detailed park plans shall provide for active recreational facilities and uses, and shall conform with the design criteria described in the specific plan document for Planning Area 11 and with the requirements of the Valley-Wide Recreation and Park District or other entity as set forth in Condition of Approval No. 3.11. THe detailed park plans shall include landscape and irrigation plans and documentation evidencing a permanent maintenance mechanism for the park and its facilities. Prior to the issuance of the 250th occupancy permit anywhere within the area described as Planning Areas 50a, 50b, 51, 52, 53, 57, 58, 60, and 61, the park designated as Planning Area 55 shall be constructed in accordance with approved park plans and fully operable. (Amended by the Planning Commission on 10/25/95.)
015 - Planning
UNKNOWN
SP -PERRIS UNION HIGH SCHOOLStatus
Impacts to the Romoland School District and the Perris Union High School District shall be mitigated in accordance with the provisions of the School Mitigation Agreements by and among the Romoland School District, Perris Union High School District, Community Facilities District No. 91-1 of the Romoland School District, and Andre Van Der Poel, Philip G. Troost, Kenneth Menifee, Inc., Andrew Choi, M.D., and John M. Wilhelm executed by the districts on February 13, 1996. All school sites shall meet the requirements of the district in terms of size, location, access, and absence from environmental constraint. (Amended by the Planning Commission at its hearing on 10/25/96.)
015 - Planning
UNKNOWN
SP -PLANNING AREA 11Status
Prior to the issuance of any residential building permits within Planning Areas 1, 2, 7, 8, 10, or 15, detailed park plans shall be submitted to and approved by the Planning department and the Valley-Wide Recreation and Park District or other entity as set forth in Condition of Approval No. 3.11 for the park site identified as Planning area 11. The detailed park plans shall provide for active recreational facilities and uses, and shall conform with the design criteria described in the specific plan document for Planning Area 11 and with the requirements of the Valley-Wide Recreation and Park District or other entity as set forth in Condition of Approval No. 3.11. The detailed park plans shall include landscape and irrigation plans and documentation evidencing a permanent maintenance mechanism for the park and its facilities. Prior to the issuance of the 250th occupancy permit anywhere within the area described as Planning Areas 1, 2, 7, 8, 10, and 15, the park designated as Planning Area 11 shall be constructed in accordance with approved park plans and fully operable. (Amended by the Planning Commission on 9/13/95.)
015 - Planning
UNKNOWN
SP -PLANNING AREA 19 PARKStatus
Prior to the issuance of any building permits within Planning Areas 17, 21, 26a, 26b, or 27 detailed park plans shall be submitted to and approved by the Planning Department and the Valley-Wide Recreation and Park District or other entity as set forth in condition of Approval No. 3.11 for the park site identified as Planning Area 19. The detailed park plans shall provide for active recreational facilities and uses, and shall conform with the design criteria described in the specific plan document for Planning Area 19 and with the requirements of the Valley-Wide Recreation and Park District or other entity as set forth in Condition of Approval No. 3.11. The detailed park plans shall include landscape and irrigation plans and documentation evidencing a permanent maintenance mechanism for the park and its facilities. Prior to the issuance of the 250th occupancy permit anywhere within the area described as Planning Areas 17, 21, 26a, 26b and 27, the park designated as Planning Area 19 shall be constructed in accordance with approved park plans and fully operable. (Amended by the Planning Commission on 10/25/95.)
015 - Planning
UNKNOWN
SP -PLANNING AREA 28B PARKStatus
Prior to the issuance of the 1,250th building permit anywhere within SPECIFIC PLAN NO. 293, detailed park plans shall be submitted to and approved by the Planning Department and the Valley-Wide Recreation and Park District or other entity as set forth in Condition of Approval No. 3.11 for the community park site identified as Planning Area 28b. The detailed park plans shall provide for active recreational facilities and uses, and shall conform with the design criteria described in the specific plan document for Planning Area 28b and with the requirements of the Valley-Wide Recreation and Park District or other entity as set forth in Condition of Approval No. 3.11. The detailed park plans shall include landscape and irrigation plans and documentation evidencing a permanent maintenace mechanism for the park and its facilities. Prior to the issuance of the 2,500th occupancy permit anywhere within SPECIFIC PLAN NO. 293, but not later than 10 years after issuance of the first occupancy permit anywhere within SPECIFIC PLAN NO. 293. The park designated as Planning Area 28b shall be constructed in accordance with approved park plans and fully operable. (Amended by Planning Staff prior to the Planning Commission hearing on 9/13/95.)
015 - Planning
UNKNOWN
SP -PLANNING AREA PARKStatus
Prior to the issuance of any building permits iwhtin Planning aRea 31, 33, 34, 38a, 38b, 40, 43, 44, 45a, 45b, 46, 47a or 47b detailed park plans shall be submitted to and approved by the Planning Department and the Valley-Wide Recreation and Park District or other entity as set forth in condition of Approval No. 3.11 for the park sites identified as Planning Areas 32 and 37. The detailed park plans shall provide for active reacreational facilities and uses, and shall conform with the design criteria described in the specific plan document for Planning areas 32 and 37 and with the requirements of the Valley-Wide Recreation and Park District or other entity as set forth in Condition of Approval No. 3.11. The detailed park plans shall include landscape and irrigation plans and documentation evidencing a permanent maintenance mecnanism for the park and its facilities. Prior to the issuance of the 250th occupancy permit anywhere within the area defined as Planning Areas 31, 33, 34, 35, 38a, 38b, 40,43,44,45a, 45b, 46, 47a, and 47b, the park designated as Planning Area 37 shall be constructed in accordance with approved park plans and fully operable. Prior to the issuance of the 500th occupancy permit anywhere within the area described as Planning Areas 31, 33, 34, 35, 38a, 38b, 40, 43, 44, 45a, 45b, 46, 47a, and 47b, the park designated a Planning Area 32 shall be constructed in accordance with approved park plans and fully operable. (Amended by the Planning Commission on 10/25/95.)
015 - Planning
UNKNOWN
SP -PLANNING CLEARANCE PRIORStatus
Prior to issuance of a building permit for the construction of any use contemplated by this approval, the applicant shall first obtain clearance from the Riverside County Planning Department that all pertinent conditions of approval have been satisfied with the specific plan for the phase of development in question.
015 - Planning
UNKNOWN
SP -RIPARIAN PLAN AREA 50Status
Riparian (Planning Area 50) - Dedicated during construction of Planning Area 51, or replaced by acreage in a 2:1 ratio with riparian flora planted in flow line of water in Salt Creek Channel.
015 - Planning
UNKNOWN
SP -RIPARIAN PLAN AREA 52Status
Riparian (Planning Area 52) - Dedicated during construction of Planning Area 53, or replaced by acreage in a 2:1 ration with riparian flora planted in flow line of water in Salt Creek Channel.
015 - Planning
UNKNOWN
SP -SCHOOL MITIGATIONStatus
Impacts to the Menifee Union School District shall be mitigated in accordance with the provisions of the School Facilities Mitigation agreements by and among Menifee Union School District and Lisle Miller executed August 24, 1995, and by and among Menifee Union School District and San Pedro Farm executed September 6, 1995. All school sites shall meet the requirements of the district in terms of size, location, access, and absence from environmental constraint. (Amended by the Planning Commission at its hearing on 10/25/96.)
015 - Planning-All
UNKNOWN
All-MAP - 90 DAYS TO PROTESTStatus
The land divider has 90 days from the date of approval of these conditions to protest, in accordance with the procedures set forth in Government Code Section 66020, the imposition of any and all fees, dedications, reservations and/or other exactions imposed on this project as a result of the approval or conditional approval of this project.
015 - Planning-All
UNKNOWN
All-MAP - DEFINITIONSStatus
The words identified in the following list that appear in all capitals in the attached conditions of Tentative Tract Map No. 31632 shall be henceforth defined as follows: TENTATIVE MAP = Tentative Tract Map No. 31632, Amended No. 2, dated 9/29/2004. FINAL MAP = Final Map or Parcel Map for the TENTATIVE MAP whether recorded in whole or in phases.
015 - Planning-All
UNKNOWN
All-MAP - HOLD HARMLESSStatus
The land divider or any successor-in-interest shall defend, indemnify, and hold harmless the County of Riverside COUNTY), its agents, officers, or employees from any claim, action, or proceeding against the COUNTY, its agents, officers, or employees to attack, set aside, void, or annul an approval of the COUNTY, its advisory agencies, appeal boards, or legislative body concerning the TENTATIVE MAP, which action is brought within the time period provided for in California Government Code, Section 66499.37. The COUNTY will promptly notify the land divider of any such claim, action, or proceeding against the COUNTY and will cooperate fully in the defense. If the COUNTY fails to promptly notify the land divider of any such claim, action, or proceeding or fails to cooperate fully in the defense, the land divider shall not, thereafter, be responsible to defend, indemnify, or hold harmless the COUNTY.
015 - Planning-All
UNKNOWN
All-MAP - INFRASTRUCTURE ACCESSStatus
Property Owner agrees to allow Right of Entry to other property owners within the Winchester Ranch project for the purpose of constructing any infrastructure improvements that may be a condition for any of the Winchester Ranch projects to proceed. Such infrastructure improvements shall include, but not be limited to, Roads, Sewer, Water, Storm and Drainage, Parks and Trails. There shall be no monetary or other compensation required to allow this right of entry. If property need be taken to construct the improvement, property owner may be compensated at a rate not to exceed the rate previously agreed upon by the participants in the Winchester Ranch Community Facilities Districts.
015 - Planning-All
UNKNOWN
All-MAP - PROJECT DESCRIPTIONStatus
The land division hereby permitted is to subdivide 55.59 acres into 186 residential lots and 10 openspace lots with minimum lot sizes of 6,000 square feet.
015 - Planning-All
UNKNOWN
All-SP -90 days prior to submittaStatus
Within ninety (90) days of the adoption of the final Board of Supervisors resolution, or prior to the submittal of any applications or the issuances of any permits, whichever comes first, ten (10) copies of the final specific plan document shall be submitted to the Planning Department for distribution. The documents shall include the final Board of Supervisors resolution, the final specific plan conditions of approval and zoning ordinance, and the Final EIR. A detailed list of required items and their order can be obtained from the Planning Department. (Amended by Planning Staff prior to the Planning Commission hearing on 9/13/95.)
015 - Planning-All
UNKNOWN
All-SP -AMENDMENTS TO SP 293Status
Any amendment to SPECIFIC PLAN NO. 293, even though it may affect only one portion of the specific plan, shall be accompanied by a complete specific plan document, in both paper and electronic formats, which includes the entire specific plan, including both changed and unchanged parts.
015 - Planning-All
UNKNOWN
All-SP -CHANGE,WAIVE,OR MODIFYStatus
No portion of the specific plan which purports or proposes to change, waive or modify any ordinance or other legal requirement for the development shall be considered to be part of the adopted specific plan.
015 - Planning-All
UNKNOWN
All-SP -COMMON AREAStatus
Common areas identified in the specific plan shall be owned and maintained as follows: a. A permanent master organization shall be established for the specific plan area, to assume ownership and maintenance responsibility for all common recreation, open space, circulation systems and landscaped areas. The organization may be public or private. Merger with an area-wide or regional organization shall satisfy this condition provided that such organization is legally and financially capable of assuming the responsibilities for ownership and maintenance. If the organization is a private association then neighborhood associations shall be established for each residential development, where required, and such associations may assume ownership and maintenance responsibility for neighborhood common areas. b. Unless otherwise provide for in these conditions of approval, common areas shall be conveyed to the maintenance organization as implementing development is approved or any subdivision is recorded. c. The maintenance organization shall be established prior to or concurrent with the recordation of the first land division, or issuance of any building permits for any approved development permit (use permit, plot plan, etc.).
015 - Planning-All
UNKNOWN
All-SP -CONF ORD LAWSStatus
The development of the property shall be in accordance with the mandatory requirements of all Riverside County ordinances including Ordinances Nos. 348 and 460 and state laws; and shall conform substantially with adopted SPECIFIC PLAN NO. 293 as filed in the office of the Riverside County Planning Department, unless otherwise amended.
015 - Planning-All
UNKNOWN
All-SP -DUAL WATER SYSTEMSStatus
Dual water systems shall be provided in common open space areas for the use of reclaimed water when made available by the water district.
015 - Planning-All
UNKNOWN
All-SP -ENVIRONMENTAL ASSESSMENTStatus
An environment assessment shall be conducted to determine potential environmental impacts resulting from each tract, change of zone, plot plan, specific plan amendments, or any other discretionary permit required to implement the specific plan. The environmental assessments shall be prepared as part of the review process for these implementing projects. At a minimum, the environmental assessment shall utilize the evaluation of impacts addressed in the Environmental Impact Report prepared for SPECIFIC PLAN NO. 293.
015 - Planning-All
UNKNOWN
All-SP -LAND DIV FOR PHAS OR FINAStatus
A land division filed for the purposes of phasing or financing shall not be considered an implementing development application. for passing standards, the restroom shall be abandoned.
015 - Planning-All
UNKNOWN
All-SP -MAST MAIN PRIVATEStatus
If the permanent master maintenance organization referenced in Condition of Approval No. 3.5 is a private organization, the developer shall comply with the following condition: a. Prior to recordation of any final subdivision map or issuance of building permits in the case of use permits and plot plans, the subdivider shall submit the following documents to Planning Department for review, which documents shall be subject to the approval of that department and the Office of the County Counsel: 1. A declaration of covenants, conditions and restrictions; and 2. A sample document conveying title to the purchaser of an individual lot or unit which provides that the declaration of covenants, conditions and restrictions is incorporated therein by reference. b. The declaration of covenants, conditions and restrictions submitted for review shall (a) provide for a term of 60 years, (b) provide for the establishment of a property owners' association comprised of the owners of each individual lot or unit and (c) provide for ownership of the common area by either the property owners' association of the owners of each individual lot or unit as tenants in common and (d) containing the following provisions verbatim: "Notwithstanding any provision in this Declaration to the contrary, the following provisions shall apply: 1. The property owners' association established herein shall, manage and continuously maintain the 'common area', more particularly described on Exhibit '__' attached hereto, and shall not sell or transfer the 'common area' or any part thereof, absent the prior written consent of the Planning Director of the County of Riverside or the County successor-in-interest. 2. The property owners' association shall have the right to assess the owners of each individual lot or unit for the reasonable cost of maintaining such 'common area', and shall have the right to lien the property of any such owner who defaults in the payment of a maintenance assessment. An assessement lien, once created, shall be prior to all other liens recorded subsequent to the notice of assessment or other document creating the assessment lien. 3. This Declaration shall not be terminated, 'substantially' amended or property deannexed therefrom absent the prior written consent of the Planning Director of the County of Riverside or the County's successor-in-interest. A proposed amendment shall be considered 'substantial' if it affects the extent, usage or maintenance of the 'common area'. 4. In the event of any conflict between this Declaration and the Articles of Incorporation, the Bylaws, or the property owners' association Rules and Regulations, if nay, this Declaration shall control." c. Once approved, the declaration of covenants, conditions and restrictions shall be recorded at the same time the final map is recorded.
015 - Planning-All
UNKNOWN
All-SP -MASTER MAIN PUBLICStatus
If the permanent master maintenance organization referenced in Condition of Approval No. 3.5 is a public organization, the developer shall comply with the following condition: a. Prior to the recordation of any final subdivision map, or issuance of building permits in the case of use permits and plot plans, the applicant shall convey to the County fee simple title, to all common or common open areas, free and clear of all liens, taxes, assessments, leases (recorded and unrecorded) and easement, except those easements which in the sole discretion of the County are acceptabe. As a condition precedent to the County accepting title to such areas, the subdivider shall submit the following documents to the Planning Department and the office of the County Counsel: 1. A declaration of covenants, conditions and restrictions; and 2. A sample document conveying title to the purchaser of an individual lot or unit which provides that the declaration of covenants, conditions and restrictions is incorporated therein by reference. b. The declaration of covenants, conditions and restrictions submitted for review shall (a) provide for a term of 60 years, (b) provide for the establishment of a property owners' association comprised of the owners of each individual lot or unit and (c) contain the following provisions verbatim: "Notwithstanding any provision in this Declaration to the contrary, the following provisions shall apply: 1. The property owners' association established herein shall, if dormant, be activated, by incorporation or otherwise, at the request of the County of Riverside, and the property owner's association shall unconditionally accept from the County of Riverside, upon the County's demand, title to all or any part of the 'common area', more particularly described on Exhibit '__' attached hereto. The decision to require that the association unconditionally accept title to the 'common area' shall be at the sole discretion of the County of Riverside. 2. In the event that the common area, or any part thereof, is conveyed to the property owners' association, the association, thereafter shall own such 'common area', shall manage and continuously maintain such 'common area', or any part thereof, absent the prior written consent of the Planning Director of the County of Riverside or the County's successor-in-interest. The property owners' association shall have the right to assess the owners who defaults in the payment of a maintenance assessment. An assessment lien, once created, shall be prior to all other liens recorded subsequent to the notice of assessment or other document creating the assessment lien. 3. This Declaration shall not be terminated, 'substantially' amended or property deannexed therefrom absent the prior written consent of the Planning Director of the County of Riverside or the County's successor-in-interest. A proposed amendment shall be considered 'substantial' if it affects the extent, usage or maintenance of the 'common area'. 4. In the event of any conflict between this Declaration and the Articles of Incorporation, the Bylaws, or the property owners' association Rules and Regulations, if any, this Declaration shall control." c. Once approved, the declaration of covenants, conditions and restrictions shall be recorded at the same time that the final map is recorded.
015 - Planning-All
UNKNOWN
All-SP -PLANNING AND PHASE NUMBERStatus
All planning area and phase numbers shall be maintained throughout the life of SPECIFIC PLAN NO. 293, unless changed through the approval of a specific plan amendment accompanied by a revision to the complete specific plan amendment.
015 - Planning-All
UNKNOWN
All-SP -PRECEDENCEStatus
If any of the following conditions of approval differ from the specific plan text or exhibits, the conditions enumerated herein shall take precedence.
015 - Planning-All
UNKNOWN
All-SP -PRIOR TO ADOPTIONStatus
Prior to the Board of Supervisors adoption of the resolutions and ordinances granting final approval of SPECIFIC PLAN NO. 293, COMPREHENSIVE GENERAL PLAN AMENDMENT NO. 336, AND CHANGE OF ZONE NO. 6013, the applicant shall submit to the Planning Department a legal description defining the boundaries of each planning area within SPECIFIC PLAN NO. 293.
015 - Planning-All
UNKNOWN
All-SP -PRIOR TO PHASEStatus
Prior to the submittal of any subdivision map, or other residential development application within any phase of SPECIFIC PLAN NO. 293 as defined in Table IV-1, a copy of which is attached, all portions of the phase of SPECIFIC PLAN NO. 293 within which the proposed subdivision or residential development is located, not currently within the boundaries of the Valley-Wide Recreation and Park District, shall be annexed into the Valley-Wide Recreation and Park District or a similar entity such as a County Service Area/District that has been designated by the Board of Supervisors, pursuant to Section 10.35(G) of Ordinance No. 460, to receive park dedications and fees. Documentation of said annexation shall accompany all implementing residential development applications. (Amended by the Planning Commission on 9/13/95.)
015 - Planning-All
UNKNOWN
All-SP -RECYCLING PROG PLANStatus
Each planning area shall comply with the Riverside County recycling program upon the recycling plan's adoption.
015 - Planning-All
UNKNOWN
All-SP -VALIDITY DATESStatus
SPECIFIC PLAN NO. 293 shall remain valid for twenty (20) years from the date of approval. Should the project not be substantially built out in that period of time, the project proponent shall file an application for a specific plan amendment to extend the maximum life of the specific plan. For the purpose of this condition of approval, substantial build out shall be defined as the issuance of the 3,000th occupancy permit. The specific plan amendment will update the entire specific plan document to reflect current development requirements. Should this time period lapse without substantial build out or without the approval of an amendment extending this time period, SPECIFIC PLAN NO. 293 shall become null and void on October 25, 2015. (Amended by the Planning Commission on 9/13/95.)
015 - Regional Parks and Open Space
UNKNOWN
SP - DEVELOPMENT STANDARDSStatus
Prior to any project approval the development standards of Specific Plan No. 293 shall be reviewed and complied with.
015 - Transportation
UNKNOWN
MAP - DRAINAGE 1Status
The land divider shall protect downstream properties from damages caused by alteration of the drainage patterns, i.e., concentration or diversion of flow. Protection shall be provided by constructing adequate drainage facilities including enlarging existing facilities and/or by securing a drainage easement. All drainage easements shall be shown on the final map and noted as follows: "Drainage Easement - no building, obstructions, or encroachments by landfills are allowed". The protection shall be as approved by the Transportation Department.
015 - Transportation
UNKNOWN
MAP - DRAINAGE 2Status
The land divider shall accept and properly dispose of all off-site drainage flowing onto or through the site. In the event the Transportation Department permits the use of streets for drainage purposes, the provisions of Article XI of Ordinance No. 460 will apply. Should the quantities exceed the street capacity or the use of streets be prohibited for drainage purposes, the subdivider shall provide adequate drainage facilities and/or appropriate easements as approved by the Transportation Department.
015 - Transportation
UNKNOWN
MAP - OFF-SITE PHASEStatus
Should the applicant choose to phase any portion of this project, said applicant shall provide off-site access roads to County maintained roads as approved by the Transportation Department.
015 - Transportation
UNKNOWN
MAP - STD INTRO 3(ORD 460/461)Status
With respect to the conditions of approval for the referenced tentative exhibit, the land divider shall provide all street improvements, street improvement plans and/or road dedications set forth herein in accordance with Ordinance 460 and Riverside County Road Improvement Standards (Ordinance 461). It is understood that the tentative map correctly shows acceptable centerline elevations, all existing easements, traveled ways, and drainage courses with appropriate Q's, and that their omission or unacceptablility may require the map to be resubmitted for further consideration. These Ordinances and all conditions of approval are essential parts and a requirement occurring in ONE is as binding as though occurring in all. All questions regarding the true meaning of the conditions shall be referred to the Transportation Department.
015 - Transportation
UNKNOWN
MAP - TS/CONDITIONS 1Status
The Transportation Department has reviewed the traffic study submitted for the referenced project. The study has been prepared in accordance with County-approved guidelines. We generally concur with the findings relative to traffic impacts. The Comprehensive General Plan circulation policies require a minimum of Level of Service 'C', except that Level of Service 'D' may be allowed with Board of Supervisors' approval in community development areas at intersections of any combination of secondary highway, major highways, arterials, urban arterials, expressways or state highways and ramp intersections. The study indicates that it is possible to achieve adequate Level of Service for the following intersections based on the traffic study assumptions. I-215 NB Ramps/Newport Road I-215 SB Ramps/Newport Road Leon Road/Newport Road Leon Road/Olive Avenue Beeler Road/Newport Road Adam Street/Newport Road Rice Road/Newport Road Rice Road/Olive Avenue SR-79/Domenigoni Parkway As such, the proposed project is consistent with this General Plan policy. The associated conditions of approval incorporate mitigation measures identified in the traffic study, which are necessary to achieve or maintain the required level of service.
015 - Transportation
UNKNOWN
MAP - UTILITY INSTALL. 1Status
Electrical power, telephone, communication, street lighting, and cable television lines shall be placed underground in accordance with Ordinance 460 and 461. This also applies to existing overhead lines which are 33.6 kilovolts or below along the project frontage and within the project boundaries.
015 - Transportation
UNKNOWN
SP -AMEND GEN PLAN ROADSStatus
The project proponent shall submit an application to amend the following General Plan roads to the following classifications: a. Extend Patton Avenue west of La Ventana Road to connect with Newport Road as a 6 lane Specific Plan Roadway. The actual cross-section will be approved by the Director of Transportation. b. Upgrade Patton Avenue from La Ventana Road to State Route 79, to an Urban Arterial Highway from a Major Highway. c. Realign Patton Avenue from Rice Road to State Route 79, to match the relocation of Newport Road as identified in CGPA No. 374 (enclosure). d. Upgrade Briggs Road, from Simpson Road to McCall Road, to an Urban Arterial Highway from an Arterial Highway. e. Realign and upgrade Briggs Road, from Newport Road to Simpson Road, from a Major Highway to an Arterial Highway, as identified on page 79 of the traffic study. f. Upgrade Leon Road, from Patton Avenue to Olive Avenue, to an Urban Arterial Highway from a Major Highway. g. Upgrade Leon Road, from Holland Road to Patton Avenue, and from Olive Avenue to Grand Avenue, to an Arterial Highway from a Major Highway. h. Upgrade and connect Chambers Avenue from Briggs Road to Leon Road, to an Urban Arterial Highway from a Specific Plan Highway. i. Add El Callado Road, between Simpson Road and relocated State Route 79. j. Extend Holland Road as a Major roadway, easterly from Beeler Road, to provide the new connection between Beeler Road and Winchester Road. k. Delete from the Circulation Element of the General Plan the following facilities: Matthews Road, from Sherman Road to Grand Avenue; La Ventana Road, from Patton Road to Olive Avenue; Eucalyptus Road, from Patton Road to Olive Avenue; Beeler Road, from Patton Road to Olive Avenue; Chambers Avenue, from Menifee Road to Briggs Road.
015 - Transportation
UNKNOWN
SP -ACCESS TO PATTONStatus
Access onto Patton Avenue must be kept to a minimum of 1,320'. Any variation of the General Plan Urban Arterial cross-section standard will need to be approved by the Development Review Engineer, Riverside County Transportation Department.
015 - Transportation
UNKNOWN
SP -COMPLY W/REQ FROM TRANSStatus
The subdivider shall comply with the requirements set forth in the Riverside County Transportation Department's letter dated 5/14/96, a copy of which is attached. (Amended by the Board of Supervisors at its hearing on 5/14/96.)
015 - Transportation
UNKNOWN
SP -DEVELOPMENT STANDARDSStatus
Prior to any project approval the development standards of Specific Plan No. 293 shall be reviewed and complied with.
015 - Transportation
UNKNOWN
SP -EMWD MULTI PURP TRAILSStatus
The project is required to coordinate its efforts in developing trails within the flood control channel with Eastern Municipal Water District, which is developing a plan of multi-purpose trails along the Salt Creek Channel.
015 - Transportation
UNKNOWN
SP -TRAFFIC ATTRACT/GENERATORStatus
The proposed project will be a substantial traffic attractor/generator. As such, the project proponent shall incorporate such demand management programs as may be appropriate to comply with the goals and objectives of the Regional Mobility Plan, Air Quality Management Plan, and Congestion Management Program, including: a. The establishment of a Transportation Management Association. b. The provision of on-site park and ride facilities. c. Design provisions to accommodate transit services. All as approved and confirmed by the Transportation Department.
015 - Transportation
UNKNOWN
SP -TRAFFIC SIGNAL MIT PROGStatus
The project proponent shall also participate in the Traffic Signal Mitigation Program as approved by the Board of Supervisors.
015 - Transportation
UNKNOWN
SP -TRAFFIC SIGNALSStatus
The project is required to provide the following traffic signals (see attached Exhibit GG, page 79, from the approved traffic study) as warranted by subsequent traffic studies prepared for development within the Specific Plan 293 boundaries: Briggs Road (NS) at: -Simpson Road -Olive Avenue -Patton Avenue La Ventana Road (NS) at: -Simpson Road -Olive Avenue -Patton Avenue La Ventana Loop Road (NS) at: -Patton Road Leon Road (NS) at: -Loop Road -Olive Avenue -Patton Avenue -North Loop Road -Central Loop Road -South Loop Road Eucalyptus Road (NS) at: -Olive Avenue West Loop Road (NS) at: -Patton Avenue Rice Road (NS) at: -Patton Avenue
015 - Transportation
UNKNOWN
SP -TRAFFIC STUDIESStatus
Traffic studies are required for all subsquent development proposals within the boundaries of the proposed Specific Plan No. 293.
050 - E Health
Prior To Map Recordation
E0T2-NOISE STUDY REQUIREDStatus
Provide an original copy of a noise study to the Industrial Hygiene program for review and approval. For any questions, please contact Office of Industrial Hygiene at (951) 955-8980.
050 - E Health
Prior To Map Recordation
EOT3- SOLID WASTE SERVICEStatus
Prior to map recordation, the project must provide documentation from an approved waste hauler in regards to solid waste service. Please call (951)955-8980 for additional details.
050 - E Health
Prior To Map Recordation
EOT4 - REQ E HEALTH DOCUMENTSStatus
Prior to map recordation, provide the following documents to the Riverside County Environmental Health Department: 1.Provide current documentation from the appropriate purveyor(s) for the establishment of water and/or sewer service for this project. 2. Provide documentation from an approved waste hauler in regards to solid waste service. Please call (951)955-8980 for additional details. 3.Provide written clearance from DEH Environmental Cleanup Programs. Please note that an Environmental Site Assessment, Phase 1 study may be required at their discretion. For further information, please contact (951) 955-8982. (This Extension of Time condition may be considered "Met" if it duplicates another similar condition issued by this department)
050 - E Health
Prior To Map Recordation
MAP - ANNEX FINALIZEDStatus
Annexation proceedings must be finalized with the applicable purveyor for sanitation service.
050 - E Health
Prior To Map Recordation
MAP - MONEYStatus
Financial arrangements (securities posted) must be made for the water improvement plans and be approved by County Counsel.
050 - E Health
Prior To Map Recordation
MAP - SEWER PLAN - COUNTYStatus
A sewer system shall have mylar plans and specifications as approved by the District, the County Survey Department and the Department of Environmental Health.
050 - E Health
Prior To Map Recordation
MAP - WATER PLANStatus
A water system shall have plans and specifications approved by the water company and the Department of Environmental Health.
050 - Fire
Prior To Map Recordation
MAP-#46-WATER PLANSStatus
The applicant or developer shall furnish one copy of the water system plans to the Fire Department for review. Plans shall be signed by a registered civil engineer, containing a Fire Department approval signature block, and shall conform to hydrant type, location, spacing and minimum fire flow. Once plans are signed by the local water company, the originals shall be presented to the Fire Department for signature.
050 - Fire
Prior To Map Recordation
MAP-#53-ECS-WTR PRIOR/COMBUSStatus
Ecs map must be stamped by the Riverside County Surveyor with the following note: The required water system, including fire hydrants, shall be installed and accepted by the appropriate water agency prior to any combustible building material placed on an individual lot.
050 - Flood
Prior To Map Recordation
MAP ADP FEESStatus
A notice of drainage fees shall be placed on the environmental constraint sheet and final map. The exact wording of the note shall be as follows: NOTICE OF DRAINAGE FEES Notice is hereby given that this property is located in the Salt Creek Channel, Winchester-North Hemet Area Drainage Plan which was adopted by the Board of Supervisors of the County of Riverside pursuant to Section 10.25 of Ordinance 460 and Section 66483, et seq, of the Government Code and that said property is subject to fees for said drainage area. Notice is further given that, pursuant to Section 10.25 of Ordinance 460, payment of the drainage fees shall be paid with cashier's check or money order only to the Riverside County Flood Control and Water Conservation District at the time of issuance of the grading or building permit for said parcels, whichever occurs first, and that the owner of each parcel, at the time of issuance of either the grading or building permit, shall pay the fee required at the rate in effect at the time of issuance of the actual permit.
050 - Flood
Prior To Map Recordation
MAP BMP - MAINT & INSPECTStatus
Unless an alternate viable maintenance entity is established, the CC&R's for the development's Homeowners Association (HOA) shall contain provisions for all structural BMPs to be inspected, and if required, cleaned no later than October 15 each year. The CC&R's shall identify the entity that will inspect and maintain all structural BMP's within the project boundaries. A copy of the CC&R's shall be submitted to the District for review and approval.
050 - Flood
Prior To Map Recordation
MAP OFFSITE EASE OR REDESIGNStatus
Offsite drainage facilities shall be located within dedicated drainage easements obtained from the affected property owner(s). Document(s) shall be recorded and a copy submitted to the District prior to recordation of the final map. If the developer cannot obtain such rights, the map should be redesigned to eliminate the need for the easement.
050 - Flood
Prior To Map Recordation
MAP ONSITE EASE ON FINAL MAPStatus
Onsite drainage facilities located outside of road right of way shall be contained within drainage easements shown on the final map. A note shall be added to the final map stating, "Drainage easements shall be kept free of buildings and obstructions".
050 - Flood
Prior To Map Recordation
MAP WATERS OF U.S.-HEC, PERMITStatus
A portion of the proposed project s in a floodplain and may affect "waters of the United States", "wetlands" or "jurisdictional streambeds", therefore, in accordance with the requirements of the National Flood Insurance Program and Related Regulations (44 CFR, Parts 59 through 73) and County Ordinance No. 458: a. A flood study consisting of HEC-2/HEC-RAS calculations, cross sections, maps and other data should be prepared to the satisfaction of the Federal Emergency Management Agency (FEMA) and the District for the purpose of revising the effective Flood Insurance Rate Map of the project site. The study shall be submitted with the related project improvement plans. Final Building Inspections for lots impacted by the FEMA floodplain shall not be issued until a Letter of Map Revision (LOMR) is obtained from FEMA. The applicant shall be responsible for payment of all processing fees required by FEMA for the CLOMR and LOMR. FEMA submittals for a CLOMR shall be reviewed by the District on a fee for service basis. A fee in conformance with the requirements of 44 CFR Parts 65, 70 and subsequent final rules shall be required prior to final map approval to cover the cost of processing the LOMR. Payment of all District fees and deposits for processing of FEMA submittals shall be made directly to the District. Fees for processing FEMA submittals shall be in addition to regular District plan check fees. b. A copy of appropriate correspondence and necessary permits from those government agencies from which approval is required by Federal or State law (such as Corps of Engineers 404 permit or Department of Fish and Game 1603 agreement) should be provided to the District prior to the final District approval of the project.
050 - Flood
Prior To Map Recordation
MAP WRITTEN PERM FOR GRADINGStatus
Written permission shall be obtained from the affected property owners allowing the proposed grading and/or facilities to be installed outside of the tract boundaries. A copy of the written authorization shall be submitted to the District for review and approval.
050 - Flood
Prior To Map Recordation
XXM-3 ITEMS TO ACCEPT SDStatus
Inspection and maintenance of the storm drain system to be constructed with this tract must be performed by either the County Transportation Department or the Flood Control District. The engineer (owner) must request in writing that one of these agencies accept the proposed storm drain system. The request shall note the project number, location, briefly describe the system (sizes and lengths) and include an exhibit that shows the proposed alignment. The request to the District shall be addressed to Warren D. Williams, General Manager-Chief Engineer, Attn: Stuart E. McKibbin, Chief of the Planning Division. If the District is willing to maintain the proposed drainage system items must be accomplished prior to recordation of the final map or starting construction of the drainage facility: 1) the developer shall submit to the District the preliminary title reports, plats and legal descriptions for all right of way to be conveyed to the District and secure that right of way to the satisfaction of the District; 2) an agreement with the District must be executed which establishes the terms and conditions of inspection, operation and maintenance; and 3) plans for the facility must be signed by the District's General Manager-Chief Engineer. The plans cannot be signed prior to execution of the agreement. An application to draw up an agreement must be submitted to the attention of Mark Wills. All right of way transfer issues must be coordinated with Morris Reynolds of the District's Right of Way Section. The engineer/developer will need to submit proof of flood control facility bonds and a certificate of insurance to the District's Inspection section before a pre-construction meeting can be scheduled.
050 - Flood
Prior To Map Recordation
XXM-SUBMIT PLANSStatus
A copy of the improvement plans, grading plans, final map, environmental constraint sheet and any other necessary documentation along with supporting hydrologic and hydraulic calculations shall be submitted to the District for review. The plans must receive District approval prior to recordation. All submittals shall be date stamped by the engineer and include a completed Flood Control Deposit Based Fee Worksheet and the appropriate plan check fee deposit.
050 - Planning
Prior To Map Recordation
MAP - AG PRES CANCEL (1)Status
Prior to recordation of a final map, the Board of Supervisors shall have issued a certificate of final cancellation for Winchester Agricultural Preserve, 27, and Map No. 422 of associated Agricultural Preserve Case) or shall have adopted a resolution diminishing the agriculutral preserve following the expiration of the land conservation contract pursuant to a notice of nonrenewal."
050 - Planning
Prior To Map Recordation
MAP - AG/DAIRY NOTIFICATIONStatus
The land divider shall submit a detailed proposal for the notification of all initial and future purchasers of dwelling units within the subject project of the existence of dairies and/or other agricultural uses within the vicinity of the property and potential impacts resulting from those uses. Said notification shall be in addition to any notice required by Ordinance No. 625 (Riverside County Right-to-Farm Ordinance). Said approved notification shall be provided to all initial and all future purchasers of dwelling units within the subject project.
050 - Planning
Prior To Map Recordation
MAP - ANNEX TO PARK DISTRICTStatus
The land divider shall submit written proof to the County Planning Department - Development Review Division that the subject property has been annexed to Valleywide Recreation and Parks District.
050 - Planning
Prior To Map Recordation
MAP - CC&R RES POA COM. AREAStatus
The land divider shall (a) notify the Planning Department that the following documents shall be shortly, or have been, submitted to the Office of the County Counsel for the review and approval of that office, and (b) the land divider shall submit to the Office of the County Counsel the following documents: 1. A cover letter identifying the project for which approval is sought referencing the Planning Department case number(s) (a copy of this cover letter may be sent to the Planning Department to serve as notification) and identifying one individual to represent the land divider if there are any questions concerning the review of the submitted documents; and 2. One (1) copy AND one (1) original, wet signed, notarized and ready for recordation declaration of covenants, conditions, and restrictions; attached to these documents there shall be included a legal description of the property included within the covenants, conditions and restrictions and a scaled map or diagram of such boundaries, both signed and stamped by a California registered civil engineer or licensed land surveyor; and 3. A sample document conveying title to the purchaser of an individual lot or unit which provides that the declaration of covenants, conditions, and restrictions is incorporated therein by reference; and, 4. A deposit equaling three (3) hours of the current hourly fee for the Review of Covenants, Conditions and Restrictions established pursuant to County Ordinance No. 671 at the time the above referenced documents are submitted to the Office of the County Counsel for review and approval. The declaration of covenants, conditions and restrictions submitted for review shall a) provide for a minimum term of 60 years, b) provide for the establishment of a property owner's association comprised of the owners of each individual lot or unit as tenants in common, c) provide for the ownership of the common area by either the property owner's association or the owners of each individual lot or unit as tenants in common, and d) contain the following provisions verbatim: "Notwithstanding any provision in this Declaration to the contrary, the following provisions shall apply: The property owners' association established herein shall manage and continuously maintain the 'common area', more particularly described on Exhibit 'A', attached hereto, and shall not sell or transfer the 'common area' or any part thereof, absent the prior written consent of the Planning Department of the County of Riverside or the County's successor-in-interest. The property owners' association shall have the right to assess the owners of each individual lot or unit for the reasonable cost of maintaining such 'common area', and shall have the right to lien the property of any such owner who defaults in the payment of a maintenance assessment. An assessment lien, once created, shall be prior to all other liens recorded subsequent to the notice of assessment or other document creating the assessment lien. This Declaration shall not be terminated, 'substantially' amended, or property deannexed therefrom absent the prior written consent of the Planning Director of the County of Riverside or the County's successor-in-interest. A proposed amendment shall be considered 'substantial' if it affects the extent, usage, or maintenance of the 'common area' established pursuant to the Declaration. In the event of any conflict between this Declaration and the Articles of Incorporation, the Bylaws, or the property owners' association Rules and Regulations, if any, this Declaration shall control." Once approved, the copy and the original declaration of covenants, conditions and restrictions shall be forwarded by the Office of the County Counsel to the Planning Department. The Planning Department will retain the one copy for the case file, and forward the wet signed and notarized original declaration of covenents, conditions and restrictions to the County Transportation Department - Survey Division - for safe keeping until the final map is ready for recordation. The County Transportation Department - Survey Division - shall record the original declaration of covenants, conditions and restrictions in conjunction with the recordation of the final map.
050 - Planning
Prior To Map Recordation
MAP - COMPLY WITH ORD 457Status
The land divider shall provide proof to The Land Management Agency - Land Use Section that all structures for human occupancy presently existing and proposed for retention comply with Ordinance Nos. 457 and 348.
050 - Planning
Prior To Map Recordation
MAP - ECS LIQUEFACTIONStatus
An environmental constraints sheet (ECS) shall be prepared for this project. The ECS shall indicate the area of the project site that is subject to the potential hazard of liquefaction. In addition, a note shall be placed on the ECS as follows: "This site, as delineated on this ECS map and as indicated in County Geologic Report (GEO) No. 1262, is subject to the potential hazard of liquefaction. Therefore, mitigation of this hazard, in the form of remedial grading and/or structural design improvements, is required prior to placement of settlement sensitive structures on this site."
050 - Planning
Prior To Map Recordation
MAP - ECS NOTE ARCHAEOLOGICALStatus
The following Environmental Constraints note shall be placed on the ECS: "County Archaeological Report no. PD-A-3302 & 3308 were prepared for this property on 3/18/04 & 4/5/04 respectively by CRM Tech and is on file at the County of Riverside Planning Department. The property is not subject to surface alteration restrictions based on the results of the report."
050 - Planning
Prior To Map Recordation
MAP - ECS NOTE BIOLOGICALStatus
The following Environmental Constraints note shall be placed on the ECS: "County Biological Report No. PD-B-2716 was prepared for this property on 7/29/04 by Principe & Associates and is on file at the County of Riverside Planning Department. Biological resources requiring protection include, but are not limited to, burrowing owl habitat. The property is subject to biological resources restrictions based on the results of the report."
050 - Planning
Prior To Map Recordation
MAP - ECS NOTE MAP CONSTRAINTStatus
The following Environmental Constraints Note shall be placed on the ECS: "No permits allowing any grading, construction, or surface alterations shall be issued which effect the delineated constraint areas without further investigation and/or mitigation as directed by the County of Riverside Planning Department. This constraint affects lots as shown on the Environmental Constraints Sheet."
050 - Planning
Prior To Map Recordation
MAP - ECS NOTE MT PALOMAR LIGHStatus
The following Environmental Constraint Note shall be placed on the ECS: "This property is subject to lighting restrictions as required by County Ordinance No. 655, which are intended to reduce the effects of night lighting on the Mount Palomar Observatory. All proposed outdoor lighting systems shall be in conformance with County Ordinance No. 655."
050 - Planning
Prior To Map Recordation
MAP - ECS SHALL BE PREPAREDStatus
The land divider shall prepare an Environmental Constraints Sheet (ECS) in accordance with Section 2.2. E. & F. of County Ordinance No. 460, which shall be submitted as part of the plan check review of the FINAL MAP.
050 - Planning
Prior To Map Recordation
MAP - FEE BALANCEStatus
Prior to recordation, the Planning Department shall determine if the deposit based fees for the TENTATIVE MAP are in a negative balance. If so, any unpaid fees shall be paid by the land divider and/or the land divider's successor-in-interest.
050 - Planning
Prior To Map Recordation
MAP - FINAL MAP PREPARERStatus
The FINAL MAP shall be prepared by a licensed land surveyor or registered civil engineer.
050 - Planning
Prior To Map Recordation
MAP - OFFER OF TRAILSStatus
An offer of dedication to the County of Riverside for a fourteen to twenty foot (14'-20') wide regional trail along Salt Creek Channel, a ten to fourteen foot (10'-14') wide community trail along Rice Road and along northern portion of Newport Road shall be noted on both the FINAL MAP and the Environmental Constraints Sheet.
050 - Planning
Prior To Map Recordation
MAP - PREPARE A FINAL MAPStatus
After the approval of the TENTATIVE MAP and prior to the expiration of said map, the land divider shall cause the real property included within the TENTATIVE MAP, or any part thereof, to be surveyed and a FINAL MAP thereof prepared in accordance with the current County Transportation Department - Survey Division requirements, the conditionally approved TENTATIVE MAP, and in accordance with Article IX of County Ordinance No. 460.
050 - Planning
Prior To Map Recordation
MAP - QUIMBY FEES (1)Status
The land divider shall submit to the County Planning Department - Development Review Division a duly and completely executed agreement with the Valleywide Recreation and Parks District which demonstrates to the satisfaction of the County that the land divider has provided for the payment of parks and recreation fees and/or dedication of land for the TENTATIVE MAP in accordance with Section 10.35 of County Ordinance No. 460.
050 - Planning
Prior To Map Recordation
MAP - REQUIRED APPLICATIONSStatus
No FINAL MAP shall record until Change of Zone No. 6816 have been approved and adopted by the Board of Supervisors and has been made effective. This land division shall conform with the development standards of the designations and/or zones ultimately applied to the property.
050 - Planning
Prior To Map Recordation
MAP - SURVEYOR CHECK LISTStatus
The County Transportation Department - Survey Division shall review any FINAL MAP and ensure compliance with the following: A. All lots on the FINAL MAP shall be in substantial conformance with the approved TENTATIVE MAP relative to size and configuration. B. All lots on the FINAL MAP shall have a minimum lot size of 6,000 square feet net. C. All lot sizes and dimensions on the FINAL MAP shall be in conformance with the development standards of this SP zone, and with the Riverside County Integrated Project (RCIP). D. All lots on the FINAL MAP shall comply with the length to width ratios, as established by Section 3.8.C. of County Ordinance No. 460. E. All knuckle or cul-de-sac lots shall have a minimum of 35 feet of frontage measured at the front lot line. F. The common open space areas shall be shown as numbered lots on the FINAL MAP.
050 - Planning
Prior To Map Recordation
MAP - TRAIL MAINTENANCEStatus
The land divider shall form or annex to a trails maintenance district or other maintenance district approved by the County Planning Department, for the maintenance of a ten to fourteen foot (10'-14') wide community trail located along Rice and Newport Roads. The land divider, or the land divider's successors-in-interest or assignees, shall be responsible for the maintenance of the community trail easement until such time as the maintenance is taken over by the appropriate maintenance district.
050 - Planning
Prior To Map Recordation
MAP*- ECS AFFECTED LOTSStatus
The following note shall be placed on the FINAL MAP: "Environmental Constraint Sheet affecting this map is on file in the County of Riverside Transportation Department - Survey Division, in E.C.S. Book ___, Page ___.
050 - Transportation
Prior To Map Recordation
EOT4 - FINAL ACCESS AND MAINTStatus
Prior to the map recordation, the applicant shall submit a Water Quality Management Plan (WQMP) subject to the State Regional Water Quality Board Order No. (See watershed below) to Transportation Department for review and approval. However, the applicant may be required to comply with the latest version of the WQMP manual if required by the State Regional Water Quality Board. All water quality features shall be included on the grading plan. WQMP applicability checklist, templates, LID design requirements, and guidance can be found on-line at: www.rcflood.org/npdes. For any questions, please contact (951) 712-5494. Watersheds: Santa Ana No. R8-2013-0024 / Santa Margarita No. R9-2010-0016 / Whitewater No. R7-2013-0011 Additionally, prior to the map recordation, the applicant shall ensure that BMP facilities are placed in dedicated easements and that sufficient legal access to the BMPs are provided. This requirement is for both onsite and offsite property. (This Extension of Time condition may be considered "Met" if it duplicates another similar condition issued by this department)
050 - Transportation
Prior To Map Recordation
MAP - ACCESS RESTRICTIONStatus
Lot access shall be restricted on Newport Road, Olive Avenue, Rice Road and Adams Street between Newport Road to 'A' Street and 'A' Street.
050 - Transportation
Prior To Map Recordation
MAP - ASSESSMENT DISTStatus
Should this project lie within any assessment/benefit district, the applicant shall, prior to recordation, make application for and pay for their reapportionment of the assessments or pay the unit fees in the benefit district unless said fees are deferred to building permit.
050 - Transportation
Prior To Map Recordation
MAP - DEDICATIONSStatus
Newport Road shall be improved within the dedicated right-of-way in accordance with Countywide Design Standard, Exhibit L. (modified) (110'/152') *NOTE* 1. This will require a curbed landscaped median. *NOTE* 2. Sidewalk/bike path to be 12' wide ajacent to right-of-way. Rice Road shall be improved within the dedicated right-of-way in accordance with Countywide Design Standard, Exhibit 'H'. (32'/50') *NOTE* This will require a bridge 32'/50' as determined by the Transportation Department. (modified) Olive Avenue shall be improved within the dedicated right-of-way in accordance with Countywide Design Standard, Exhibit 'H'. (32'/50') Street 'A', Adams Street, Street 'L' and Street 'O' shall be improved within the dedicated right-of-way in accordance with County Standard No. 103, Section A. (46'/76') Street 'A' shall be improved within the dedicated right-of-way in accordance with Countywide Design Standard, Exhibit 'G'. (44'/74') The remaining interior streets shall improved within the dediicated right-of-way in accordance with County Standard 104, Section A. (35'/56') (modified)
050 - Transportation
Prior To Map Recordation
MAP - EASEMENT/SURStatus
Any easement not owned by a public utility, public entity or subsidiary, not relocated or eliminated prior to final map approval, shall be delineated on the final map in addition to having the name of the easement holder, and the nature of their interests, shown on the map.
050 - Transportation
Prior To Map Recordation
MAP - GRAFFITI ABATEMENT EOT1Status
The project proponent shall file an application for annexation to Landscaping and Lighting Maintenance District No. 89-1-Consolidated for graffiti abatement of walls and other permanent structures along County maintained road rights-of-way.
050 - Transportation
Prior To Map Recordation
MAP - IMP PLANSStatus
Improvement plans for the required improvements must be prepared and shall be based upon a design profile extending a minimum of 300 feet beyond the project boundaries at a grade and alignment as approved by the Riverside County Transportation Department. Completion of road improvements does not imply acceptance for maintenance by County.
050 - Transportation
Prior To Map Recordation
MAP - INTERSECTION/50' TANGENTStatus
All enterline intersections shall be at 90 degrees, plus or minus 5 degrees, with a minimum 50' tangent, measured from flowline/curbface or as approved by the Transportation Planning and Development Review Division Engineer.
050 - Transportation
Prior To Map Recordation
MAP - LANDSCAPINGStatus
The project proponent shall comply in accordance with landscaping requirements within public road rights-of-way, in accordance with Ordinance 461. Landscaping shall be installed within Olive Avenue, Newport Road, 'A' Street and Adams Street between Newport Road to 'A' Street. Landscaping plans shall be submitted on standard County Plan sheet format (24" X 36"). Landscaping plans shall be submitted with the street improvement plans. If landscaping maintenance to be annexed to County Service Area, or Landscaping and Lighting Maintenance District, landscaping plans shall depict ONLY such landscaping, irrigation and related facilities as are to be placed within the public road rights-of-way.
050 - Transportation
Prior To Map Recordation
MAP - LANDSCAPING APP. ANNEXStatus
Landscaping within public road rights-of-way shall comply with Transportation Department standards and require approval by the Transportation Department. Assurance of continuing maintenance is required by filing an application for annexation into a County Service Area, Landscaping and Lighting Maintenance District NO. 89-1-Consolidated and/or Assessment District.
050 - Transportation
Prior To Map Recordation
MAP - OFF-SITE ACCESS 1Status
The landowner/developer shall provide/acquire sufficient public off-site rights-of-way to provide for three paved access roads to a paved and maintained road. Said access roads shall be constructed in accordance with County Standard No. 106, Section B (32'/60') at a grade and alignment as approved by the Transportation Department. Should the applicant fail to provide/acquire said off-site right-of-way, the map shall be returned for redesign. The applicant shall provide the appropriate environmental clearances for said off-site improvements prior to recordation or the signature of any street improvement plans. Said off-site access road shall be the easterly extension of Newport Road to Winchester Road and the westerly extension of Newport Road to Menifee Road. Said off-site access road shall be the easterly extension of Olive Avenue to Rice Road and the westerly extension of Olive Avenue to Leon Road. Said off-site access road shall be the westerly extension of 'A' Street to Loop Road (East) and Loop Road (East to Newport Road.
050 - Transportation
Prior To Map Recordation
MAP - OFF-SITE INFOStatus
The off-site rights-of-way required for said access road(s) shall be accepted to vest title in the name of the public if not already accepted.
050 - Transportation
Prior To Map Recordation
MAP - PART-WIDTHStatus
Adams Street shall be improved with 32 feet of asphalt concrete pavement within a 45' part-width dedicated right-of-way in accordance with County Standard No. 104, Section A. (20'/30')
050 - Transportation
Prior To Map Recordation
MAP - R & B B DStatus
Prior to the recordation of the final map, or any phase thereof, the project proponent shall pay fees in accordance with Zone E of the Menifee Valley Road and Bridge Benefit District. Should the project proponent choose to defer the time of payment, a written request shall be submitted to the County, deferring said payment to the time of issuance of a building permit. Fees which are deferred shall be based upon the fee schedule in effect at the time of issuance of the permit.
050 - Transportation
Prior To Map Recordation
MAP - R & B B DStatus
Prior to the recordation of the final map, or any phase thereof, the project proponent shall pay fees in accordance with Zone E4 of the Menifee Valley Road and Bridge Benefit District. Should the project proponent choose to defer the time of payment, a written request shall be submitted to the County, deferring said payment to the time of issuance of a building permit. Fees which are deferred shall be based upon the fee schedule in effect at the time of issuance of the permit.
050 - Transportation
Prior To Map Recordation
MAP - SOILS 2Status
The developer/owner shall submit a preliminary soils and pavement investigation report addressing the construction requirements within the road right-of-way.
050 - Transportation
Prior To Map Recordation
MAP - ST DESIGN/IMPRV CONCEPTStatus
The street design and improvement concept of this project shall be coordinated with Tracts 30322 amd 30653.
050 - Transportation
Prior To Map Recordation
MAP - STREET LIGHTS-CSA/L&LMDStatus
The project proponent shall contact the County Service Area (CSA) Project Manager who determines whether the development is within an existing CSA or will require annexation into the CSA. If the project is outside boundaries of a CSA, the project proponent shall contact the Transportation Department L&LMD 89-1-C Administrator and submit the following: 1. Completed Transportation Department application 2. Appropriate fees for annexation. 3. (2)Sets of street lighting plans approved by Transportation Department. 4. "Streetlight Authorization" form from SCE, IID or other electric provider.
050 - Transportation
Prior To Map Recordation
MAP - STREET NAME SIGNStatus
The land divider shall install street name sign(s) in accordance with County Standard No. 816 as directed by the Transportation Department.
050 - Transportation
Prior To Map Recordation
MAP - STREET SWEEPINGStatus
The project proponent shall contact the County Service Area (CSA) Project Manager to file an application for annexation or inclusion into CSA for street sweeping; or enter into a similar mechanism as approved by the Transportation Department.
050 - Transportation
Prior To Map Recordation
MAP - STREETLIGHT PLANStatus
A separate street light plan is required for this project. Street lighting shall be designed in accordance with County Ordinance 460 and Streetlight Specification Chart found in Specification Section 22 of Ordinance 461. For projects within SCE boundaries use County of Riverside Ordinance 461, Standard No's 1000 or 1001. For projects within Imperial Irrigation District (IID) use IID's pole standard.
050 - Transportation
Prior To Map Recordation
MAP - STRIPING PLANStatus
A signing and striping plan is required for this project. The applicant shall be responsible for any additional paving and/or striping removal caused by the striping plan. Traffic signing and striping shall be performed by County forces with all incurred costs borne by the applicant, unless otherwise approved by the County Traffic Engineer.
050 - Transportation
Prior To Map Recordation
MAP - TRAFFIC SIGNALS 2 EOT1Status
The project proponent shall comply in accordance with traffic signal requirements within public road rights-of-way, as directed by the Transportation Department. Assurance of traffic signal maintenance is required by filing an application for annexation to Landscaping and Lighting Maintenance District No. 89-1-Consolidated for the required traffic signal(s).
050 - Transportation
Prior To Map Recordation
MAP - TS/DESIGNStatus
The project proponent shall be responsible for the design of a traffic signal at the intersections of: - Rice Road/Newport Road with fee credit eligibility or as approved by the Transportation Department. Installation of the signal shall be per 90.TRANS.2.
050 - Transportation
Prior To Map Recordation
MAP - TS/GEOMETRICSStatus
The intersection of Rice Road/Newport Road shall be improved to provide the following geometrics: Northbound: One left turn lane, two through lane. Southbound: One left turn lane, two through lane. Eastbound: One left turn lane, three through lanes. Westbound: One left turn lane, three through lanes. Any off-site widening required to provide these geometrics shall be the responsibility of the landowner/developer, or as approved by the Transportation Department.
050 - Transportation
Prior To Map Recordation
MAP - UTILITY PLAN EOT1Status
Electrical power, telephone, communication, street lighting, and cable television lines shall be designed to be placed underground in accordance with ordinance 460 and 461, or as approved by the Transportation Department. The applicant is responsible for coordinating the work with the serving utility company. This also applies to existing overhead lines which are 33.6 kilovolts or below along the project frontage and between the nearest poles offsite in each direction of the project site. A disposition note describing the above shall be reflected on design improvement plans whenever those plans are required. A written proof for initiating the design and/or application of the relocation issued by the utility company shall be submitted to the Transportation Department for verification purposes.
050 - Transportation
Prior To Map Recordation
MAP-NEWPORT EXT CFD MENIFEE-79Status
Prior to the recordation of the final map, a Community Facilities District (CFD) or other funding mechanism acceptable to the Transportation Department shall be formed and ready to fund for the construction of the extension of Newport Road from Menifee Road to SR-79, as determined by the Transportation Department.
060 - BS-Grade
Prior To Grading Permit Issuance
Grade-EOT3- APPROVED WQMPStatus
Prior to the issuance of a grading permit, the owner / applicant shall submit to the Building & Safety Department Engineering Division evidence that the project - specific Water Quality Management Plan (WQMP) has been approved by the Riverside County Flood Control District or Riverside County Transportation Department and that all approved water quality treatment control BMPs have been included on the grading plan.
060 - BS-Grade
Prior To Grading Permit Issuance
Grade-EOT3- PRE-CONSTRUCTION MTGStatus
Upon receiving grading plan approval and prior to the issuance of a grading permit, the applicant is required to schedule a pre-construction meeting with the Building and Safety Department Environmental Compliance Division.
060 - BS-Grade
Prior To Grading Permit Issuance
Grade-EOT3- SWPPP REVIEWStatus
Grading and construction sites of "ONE" acre or larger required to develop a STORM WATER POLLUTION PREVENTION PLAN (SWPPP) - the owner/applicant shall submit the SWPPP to the Building and Safety Department Environmental Compliance Division for review and approval prior to issuance of a grading permit.
060 - BS-Grade
Prior To Grading Permit Issuance
Grade-EOT3-BMP CONST NPDES PERMITStatus
Prior to the issuance of a grading permit, the owner / applicant shall obtain a BMP (Best Management Practices) Permit for the monitoring of the erosion and sediment control BMPs for the site. The Department of Building and Safety will conduct NPDES (National Pollutant Discharge Elimination System) inspections of the site based on Risk Level to verify compliance with the Construction General Permit, Stormwater ordinances and regulations until completion of the construction activities, permanent stabilization of the site and permit final.
060 - BS-Grade
Prior To Grading Permit Issuance
Grade-EOT4 - REQ BMP SWPPP WQMPStatus
Prior to the issuance of a grading permit, the owner / applicant shall obtain a BMP (Best Management Practices) Permit for the monitoring of the erosion and sediment control BMPs for the site. The Department of Building and Safety will conduct NPDES (National Pollutant Discharge Elimination System) inspections of the site based on Risk Level to verify compliance with the Construction General Permit, Stormwater ordinances and regulations until completion of the construction activities, permanent stabilization of the site and permit final. Grading and construction sites of "ONE" acre or larger required to develop a STORM WATER POLLUTION PREVENTION PLAN (SWPPP) - the owner/applicant shall submit the SWPPP to the Building and Safety Department Environmental Compliance Division for review and approval prior to issuance of a grading permit. If a Water Quality Management Plan (WQMP) is required, the owner / applicant shall submit to the Building & Safety Department, the approved project - specific Water Quality Management Plan (WQMP) and ensure that all approved water quality treatment control BMPs have been included on the grading plan. (This Extension of Time condition may be considered "Met" if it duplicates another similar condition issued by this department)
060 - BS-Grade
Prior To Grading Permit Issuance
Grade-MAP-G1.4 NPDES/SWPPPStatus
Prior to issuance of any grading or construction permits - whichever comes first - the applicant shall provide the Building and Safety Department evidence of compliance with the following: "Effective March 10, 2003 owner operators of grading or construction projects are required to comply with the N.P.D.E.S. (National Pollutant Discharge Elimination System) requirement to obtain a construction permit from the State Water Resource Control Board (SWRCB). The permit requirement applies to grading and construction sites of "ONE" acre or larger. The owner operator can comply by submitting a "Notice of Intent" (NOI), develop and implement a STORM WATER POLLUTION PREVENTION PLAN (SWPPP) and a monitoring program and reporting plan for the construction site. For additional information and to obtain a copy of the NPDES State Construction Permit contact the SWRCB at (916) 341-5455. Additionally, at the time the county adopts, as part of any ordinance, regulations specific to the N.P.D.E.S., this project (or subdivision) shall comply with them.
060 - BS-Grade
Prior To Grading Permit Issuance
Grade-MAP-G2.1 GRADING BONDSStatus
Grading in excess of 199 cubic yards will require performance security to be posted with the Building and Safety Department. Single Family Dwelling units graded one lot per permit and proposing to grade less than 5,000 cubic yards are exempt.
060 - BS-Grade
Prior To Grading Permit Issuance
Grade-MAP-G2.14OFFSITE GDG ONUSStatus
Prior to the issuance of a grading permit, it shall be the sole responsibility of the owner/applicant to obtain any and all proposed or required easements and/or permissions necessary to perform the grading herein proposed.
060 - BS-Grade
Prior To Grading Permit Issuance
Grade-MAP-G2.2 IMPORT / EXPORTStatus
In instances where a grading plan involves import or export, prior to obtaining a grading permit, the applicant shall have obtained approval for the import/export location from the Building and Safety Department. Additionally, if either location was not previously approved by an Environmental Assessment, prior to issuing a grading permit a Grading Environmental Assessment shall be submitted to the Planning Director for review and comment and to the Building and Safety Department Director for approval.
060 - BS-Grade
Prior To Grading Permit Issuance
Grade-MAP-G2.3SLOPE EROS CL PLANStatus
Erosion control- landscape plans, required for manufactured slopes greater than 3 feet in vertical height, are to be signed by a registered landscape architect and bonded per the requirements of Ordinance 457, see form 284-47.
060 - BS-Grade
Prior To Grading Permit Issuance
Grade-MAP-G2.4GEOTECH/SOILS RPTSStatus
Geotechnical soils reports, required in order to obtain a grading permit, shall be submitted to the Building and Safety Department's Grading Division for review and approval prior to issuance of a grading permit. All grading shall be in conformance with the recommendations of the geotechnical/soils reports as approved by Riverside County.* *The geotechnical/soils, compaction and inspection reports will be reviewed in accordance with the RIVERSIDE COUNTY GEOTECHNICAL GUIDELINES FOR REVIEW OF GEOTECHNICAL AND GEOLOGIC REPORTS.
060 - BS-Grade
Prior To Grading Permit Issuance
Grade-MAP-G2.7DRNAGE DESIGN Q100Status
All grading and drainage shall be designed in accordance with Riverside County Flood Control & Water Conservation District's conditions of approval regarding this application. If not specifically addressed in their conditions, drainage shall be designed to accommodate 100 year storm flows. Additionally, the Building and Safety Department's conditional approval of this application includes an expectation that the conceptual grading plan reviewed and approved for it complies or can comply with any WQMP (Water Quality Management Plan) required by Riverside County Flood Control and Water Conservation District.
060 - E Health
Prior To Grading Permit Issuance
EOT2-PHASE I ESA REQUIREDStatus
A Phase I Environmental Site Assessment is required to be submitted to the Department of Environmental Health for review and approval. Contact the Environmental Cleanup Programs at (951)-955-8980 for further information.
060 - Flood
Prior To Grading Permit Issuance
MAP ADP FEESStatus
This site is located within the limits of the Salt Creek Channel, Winchester-North Hemet Area Drainage Plan for which drainage fees have been adopted. Drainage fees shall be paid with cashier's check or money order only to the District at the time of the issuance of grading permits for the approved parcels or at the time of issuance of building permits if no grading permits are issued for the parcels and may be paid, at the option of the land owner, in pro rata amounts. The amount of the drainage fee required to be paid shall be the amount that is in effect for the particular Area Drainage Plan at the time of issuance of the grading permits or issuance of the building permits if grading permits are not issued.
060 - Flood
Prior To Grading Permit Issuance
MAP EROS CNTRL AFTER RGH GRADStatus
Temporary erosion control measures shall be implemented immediately following rough grading to prevent deposition of debris onto downstream properties or drainage facilities. Plans showing these measures shall be submitted to the District for review.
060 - Flood
Prior To Grading Permit Issuance
MAP OBTAIN CLOMRStatus
Unless the District has already revised the map, the developer will be required to obtain a Conditional Letter of Map Revision (CLOMR) from FEMA prior to issuance of grading permits. Alternatively, the Chief Engineer may approve grading once the construction of the District's Salt Creek Channel project is complete, the plans for the removal of the Rice Road obstruction are approved and bonded and the developer has submitted hydraulic studies showing that the 100-year flood plain is contained in the channel.
060 - Flood
Prior To Grading Permit Issuance
MAP OFFSITE EASE OR REDESIGNStatus
Offsite drainage facilities shall be located within dedicated drainage easements obtained from the affected property owner(s). Document(s) shall be recorded and a copy submitted to the District prior to recordation of the final map. If the developer cannot obtain such rights, the map should be redesigned to eliminate the need for the easement.
060 - Flood
Prior To Grading Permit Issuance
MAP PHASINGStatus
If the tract is built in phases, each phase shall be protected from the 1 in 100 year tributary storm flows.
060 - Flood
Prior To Grading Permit Issuance
XXM-SUBMIT PLANSStatus
A copy of the improvement plans, grading plans and any other necessary documentation along with supporting hydrologic and hydraulic calculations shall be submitted to the District for review. The plans must receive District approval prior to issuance of grading permits. All submittals shall be date stamped by the engineer and include a completed Flood Control Deposit Based Fee Worksheet and the appropriate plan check fee deposit.
060 - Planning
Prior To Grading Permit Issuance
0060 – Planning – Finalize MOU for Parks in SP00293Status
Prior to issuance of the grading permit, finalization of the Memorandum of Understanding (MOU) for the Public Parks Implementation Agreement for Specific Plan No. 293 is required. Satisfaction of this condition of approval can only be determined by the TLMA Director or TLMA Assistant Director.
060 - Planning
Prior To Grading Permit Issuance
MAP - AG PRSRV CANCEL (2)Status
Prior to issuance of a grading permit, the Board of Supervisors shall have issued a certificate of final cancellation for Winchester Agricultural Preserve 27, map no. 422 of AG 931 or shall have adopted a resolution diminishing or disestablishing the agricultural preserve following the expiration of the land conservation contract pursuant to a notice of nonrenewal.
060 - Planning
Prior To Grading Permit Issuance
MAP - BURROWING OWL SURVEYStatus
Pursuant to Objective 6 of the Species Account for the Burrowing Owl included in the Western Riverside County Multiple Species Habitat Conservation Plan, within 30 days prior to the issuance of a grading permit, a pre-construction presence/absence survey for the burrowing owl shall be conducted by a qualified biologist and the results of this presence/absence survey shall be provided in writing to the County Biologist. If it is determined that the project site is occupied by the Burrowing Owl, take of "active" nests shall be avoided. However, when the Burrowing Owl is present outside of the nesting season (March 1 through August 15) passive relocation through use of one way doors and collapse of burrows may occur provided such relocation is supervised by a qualified biologist. Occupation of this species on the project site may result in the need to revise grading plans so that take of "active" nests is avoided or alternatively, a grading permit may be issued once the species has been passively relocated.
060 - Planning
Prior To Grading Permit Issuance
MAP - COMMUNITY TRAIL ESMNTStatus
The land divider/permit holder shall cause grading plans to be prepared which delineates grading adjacent to or within a proposed trail easement adjacent to lot numbers 105, 182-186, 151, 152, 142-144, 1-16, as delineated on the TENTATIVE MAP. Said grading must conform to the trail standards of the Comprehensive General Plan.
060 - Planning
Prior To Grading Permit Issuance
MAP - DESIGN PLANSStatus
Design plans for the common areas specifying the location and extent of landscaping and irrigation systems as specified in Riverside County Ordinance No. 348, Section 18.12, and Sections 19.300 through 19.304, and circulation (vehicular, pedestrian, equestrian and/or bicycle) shall be submitted during the review process for development applications, which incorporate common areas. Additionally, all proposed structures shall be shown on said plans. This condition implements 30.PLANNING.04 of the Specific Plan.
060 - Planning
Prior To Grading Permit Issuance
MAP - FEE BALANCEStatus
Prior to issuance of grading permits, the Planning Department shall determine if the deposit based fees are in a negative balance. If so, any outstanding fees shall be paid by the applicant/developer.
060 - Planning
Prior To Grading Permit Issuance
MAP - GRADING PLAN REVIEWStatus
The land divider/permit holder shall cause a plan check application for a grading plan to be submitted to the ounty T.L.M.A - Land Use Division for review by the County Department of Building and Safety - Grading Division. Said grading plan shall be in conformance with the approved tentative map, in ompliance with County Ordinance No. 457, and the conditions of approval for the tentative map.
060 - Planning
Prior To Grading Permit Issuance
MAP - NPDES COMPLIANCE (2)Status
Since this project will disturb one (1) or more acres, it will require a National Pollutant Discharge Elimination System (NPDES) Construction General Permit from the State Water Resources Control Board. Clearance for grading shall not be given until either the district or the Department of Building and Safety has determined that the project has complied with the current County requirements regarding the NPDES Construction General Permit.
060 - Planning
Prior To Grading Permit Issuance
MAP - SECTION 1601/1603 PERMITStatus
Should any grading or construction be proposed within or along the banks of any natural watercourse or wetland located either on-site or on any required off-site improvement areas, the land divider/permit holder shall provide written notification to the County Planning Department that the appropriate California Department of Fish and Game notification pursuant to Sections 1601/1603 of the California Fish and Game Code has taken place. Or, the land divider shall obtain an "Agreement Regarding Proposed Stream or Lake Alteration" (Section 1601/1603 Permit). Copies of any agreement shall be submitted with the notification.
060 - Planning
Prior To Grading Permit Issuance
MAP - SECTION 404 PERMITStatus
Should any grading or construction be proposed within or alongside the banks of the watercourse or wetland, the land divider/permit holder shall provide written notification to the County Planning Department that the alteration of any watercourse or wetland, located either on-site or on any required off-site improvement areas, complies with the U.S. Army Corp of Engineers Nationwide Permit Conditions. Or, the land divider shall obtain a permit under Section 404 of the Clean Water Act. Copies of any agreements shall be submitted along with the notification.
060 - Planning
Prior To Grading Permit Issuance
MAP - SKR FEE CONDITIONStatus
Prior to the issuance of a grading permit, the land divider/permit holder shall comply with the provisions of Riverside County Ordinance No. 663, which generally requires the payment of the appropriate fee set forth in that ordinance. The amount of the fee required to be paid may vary depending upon a variety of factors, including the type of development application submitted and the applicability of any fee reduction or exemption provisions contained in Riverside County Ordinance No. 663. Said fee shall be calculated on the approved development project which is anticipated to be 55.59 acres gross in accordance with the TENTATIVE MAP. If the development is subsequently revised, this acreage amount may be modified in order to reflect the revised development project acreage amount. In the event Riverside County Ordinance No. 663 is rescinded, this condition will no longer be applicable. However, should Riverside County Ordinance No. 663 be rescinded and superseded by a subsequent mitigation fee ordinance, payment of the appropriate fee set forth in that ordinance shall be required.
060 - Planning
Prior To Grading Permit Issuance
MAP - TRAIL MAINTENANCEStatus
FROM DEFERRED CONDITION 50.PLANNING 010. Note: Condition seeks to have approved agreement between Flood and Valleywide for the trail along Salt Creek so improvement plans may be approved. "The land divider shall form or annex to a trails maintenance district or other maintenance district approved by the County Planning Department, for the maintenance of a ten to fourteen foot (10'-14') wide community trail located along Rice and Newport Roads. The land divider, or the land divider's successors-in-interest or assignees, shall be responsible for the maintenance of the community trail easement until such time as the maintenance is taken over by the appropriate maintenance district."
060 - Planning
Prior To Grading Permit Issuance
PRJ - SP ARCHAEO M/M PROGRAMStatus
Prior to the preparation of Archaelogical Survey, the Archaelogist shall consult with the Pechanga Band of Luiseno Indians regarding the significance of archeological sites, and their proper mitigation. There shall be a tribal monitor present during the test excavation phase. Prior to excavations, there shall be an agreement in place for the return of sacred objects, religious items, or human remains to the tribe. This condition implements condition 30.PLANNING.[06] of the SPECIFIC PLAN.
060 - Planning-EPD
Prior To Grading Permit Issuance
EPD-EPD - 30 DAY BURROWING OWL SURStatus
Pursuant to Objective 6 and Objective 7 of the Species Account for the Burrowing Owl included in the Western Riverside County Multiple Species Habitat Conservation Plan, within 30 days prior to the issuance of a grading permit, a pre-construction presence/absence survey for the burrowing owl shall be conducted by a qualified biologist and the results of this presence/absence survey shall be provided in writing to the Environmental Programs Department. If it is determined that the project site is occupied by the Burrowing Owl, take of "active" nests shall be avoided pursuant to the MSHCP and the Migratory Bird Treaty Act. However, when the Burrowing Owl is present, relocation outside of the nesting season (March 1 through August 31) by a qualified biologist shall be required. The County Biologist shall be consulted to determine appropriate type of relocation (active or passive) and translocation sites. Occupation of this species on the project site may result in the need to revise grading plans so that take of "active" nests is avoided or alternatively, a grading permit may be issued once the species has been actively relocated. If the grading permit is not obtained within 30 days of the survey a new survey shall be required.
060 - Planning-EPD
Prior To Grading Permit Issuance
EPD-EPD - MBTA SURVEYStatus
Birds and their nests are protected by the Migratory Bird Treaty Act (MBTA) and California Department of Fish and Wildlife (CDFW) Codes. Since the project supports suitable nesting bird habitat, removal of vegetation or any other potential nesting bird habitat disturbances shall be conducted outside of the avian nesting season (February 1st through August 31st). If habitat must be cleared during the nesting season, a preconstruction nesting bird survey shall be conducted. The preconstruction nesting bird survey must be conducted by a biologist who holds a current MOU with the County of Riverside. If nesting activity is observed, appropriate avoidance measures shall be adopted to avoid any potential impacts to nesting birds. The nesting bird survey must be completed no more than 3 days prior to any ground disturbance. If ground disturbance does not begin within 3 days of the survey date a second survey must be conducted. Prior to the issuance of a grading permit the project proponent must provide written proof to the Riverside County Planning Department, Environmental Programs Division (EPD) that a biologist who holds an MOU with the County of Riverside has been retained to carry out the required survey. Documentation submitted to prove compliance prior to grading permit issuance must at a minimum include the name and contact information for the Consulting Biologist and a signed statement from the Consulting Biologist confirming that they have been contracted by the applicant to conduct a Preconstruction Nesting Bird Survey. In some cases EPD may also require a Monitoring and Avoidance Plan prior to the issuance of a grading permit. Prior to finalization of a grading permit or prior to issuance of any building permits the projects consulting biologist shall prepare and submit a report, documenting the results of the survey, to EPD for review.
060 - Transportation
Prior To Grading Permit Issuance
EOT4 - FINAL WQMP FOR GRADINGStatus
This condition would apply when grading occurs before map recordation. Prior to the issuance of a grading permit, the applicant shall submit a Water Quality Management Plan (WQMP) subject to the State Regional Water Quality Board Order No. (See watershed below) to Transportation Department for review and approval. However, the applicant may be required to comply with the latest version of the WQMP manual if required by the State Regional Water Quality Board. All water quality features shall be included on the grading plan. WQMP applicability checklist, templates, LID design requirements, and guidance can be found on-line at: www.rcflood.org/npdes. For any questions, please contact (951) 712-5494. atersheds: Santa Ana No. R8-2013-0024 / Santa Margarita No. R9-2010-0016 / Whitewater No. R7-2013-0011 (This Extension of Time condition may be considered "Met" if it duplicates another similar condition issued by this department)
080 - BS-Grade
Prior To Building Permit Issuance
Grade-MAP - ROUGH GRADE APPROVALStatus
Prior to the issuance of any building permit, the applicant shall obtain rough grade approval and/or approval to construct from the Building and Safety Department. The Building and Safety Department must approve the completed grading of your project before a building permit can be issued. Rough Grade approval can be accomplished by complying with the following: 1.Submitting a "Wet Signed" copy of the Soils Compaction Report containing substantiating data from the Soils Engineer (registered geologist or certified geologist, civil engineer or geotechnical engineer as appropriate) for his/her certification of the project. 2.Submitting a "Wet Signed" copy of the Rough Grade certification from a Registered Civil Engineer certifying that the grading was completed in conformance with the approved grading plan. 3.Requesting a Rough Grade Inspection and obtaining rough grade approval from a Riverside County inspector. 4.Rough Grade Only Permits: In addition to obtaining all required inspections and approval of all final reports, all sites permitted for rough grade only shall provide 100 percent vegetative coverage to stabilize the site prior to receiving a rough grade permit final. Prior to release for building permit, the applicant shall have met all rough grade requirements to obtain Building and Safety Department clearance.
080 - BS-Grade
Prior To Building Permit Issuance
Grade-MAP-G3.1NO B/PMT W/O G/PMTStatus
Prior to issuance of any building permit, the property owner shall obtain a grading permit and/or approval to construct from the Grading Divisin of the Building and Safety Department.
080 - Fire
Prior To Building Permit Issuance
MAP-#50C-TRACT WATER VERIFICAStatus
The required water system, including all fire hydrant(s), shall be installed and accepted by the appropriate water agency and the Riverside County Fire Department prior to any combustible building material placed on an individual lot. Contact the Riverside County Fire Department to inspect the required fire flow, street signs, all weather surface, and all access and/or secondary. Approved water plans must be a the job site.
080 - Flood
Prior To Building Permit Issuance
MAP ADP FEESStatus
This site is located within the limits of the Salt Creek Channel/Winchester/North Hemet Area Drainage Plan for which drainage fees have been adopted. Drainage fees shall be paid with cashier's check or money order only to the District at the time of the issuance of grading permits for the approved parcels or at the time of issuance of building permits if no grading permits are issued for the parcels and may be paid, at the option of the land owner, in pro rata amounts. The amount of the drainage fee required to be paid shall be the amount that is in effect for the particular Area Drainage Plan at the time of issuance of the grading permits or issuance of the building permits if grading permits are not issued.
080 - Flood
Prior To Building Permit Issuance
XXM-SUBMIT PLANSStatus
A copy of the improvement plans, grading plans and any other necessary documentation along with supporting hydrologic and hydraulic calculations shall be submitted to the District for review. The plans must receive District approval prior to issuance of building permits. All submittals shall be date stamped by the engineer and include a completed Flood Control Deposit Based Fee Worksheet and the appropriate plan check fee deposit.
080 - Planning
Prior To Building Permit Issuance
0080 – Planning – Finalize MOU for Parks in SP00293Status
Prior to issuance of a building permit, finalization of the Memorandum of Understanding (MOU) for the Public Parks Implementation Agreement for Specific Plan No. 293 is required. Satisfaction of this condition of approval can only be determined by the TLMA Director or TLMA Assistant Director.
080 - Planning
Prior To Building Permit Issuance
MAP - BUILDING SEPARATION 2Status
Building separation between all buildings shall not be less than ten (10) feet. Additional encroachments are only allowed as permitted by County Ordinance No. 348.
080 - Planning
Prior To Building Permit Issuance
MAP - CONFORM FINAL SITE PLANStatus
Final clearance shall be obtained from the County Planning Department - Development Review Division stipulating that the building plans submitted conform to the approved Final Plan of Development.
080 - Planning
Prior To Building Permit Issuance
MAP - DESIGN PLANSStatus
Design plans for the common areas specifying the location and extent of landscaping and irrigation systems as specified in Riverside County Ordinance No. 348, Section 18.12, and Sections 19.300 through 19.304, and circulation (vehicular, pedestrian, equestrian and/or bicycle) shall be submitted during the review process for development applications, which incorporate common areas. Additionally, all proposed structures shall be shown on said plans. THIS CONDITION WAS DEFERRED FROM 60.PLANNING.23
080 - Planning
Prior To Building Permit Issuance
MAP - ENTRY MONUMENT PLOT PLANStatus
The land divider/permit holder shall file four (4) sets of an Entry Monument and Gate plot plan to the County Planning Department for review and approval. Said plan shall be submitted to the Department in the form of a plot plan application pursuant to County Ordinance No. 348, Section 18.30.a.(1) (Plot Plans not subject to the California Environmental Quality Act and not subject to review by any governmental agency other than the Planning Department), along with the current fee. The plan shall be in compliance with Section 18.12, and the TENTATIVE MAP conditions of approval. The plot plan shall contain the following elements: 1. A color photosimulation of a frontal view of all/the entry monument(s) and gate(s) with landscaping. 2. A plot plan of the entry monuments) and/or gate(s) with landscaping drawn to an engineer's scale. If lighting is planned, the location of lights, their intended direction, and proposed power shall be indicated. 3. An irrigation plan for the entry monument(s) and/or gate(s). NOTE: The requirements of this plot plan may be incorprorated with any minor plot plan required by the conditions of approval for this subdivision. However, this ENTRY MONUMENT nd GATES PLAN condition of approval shall be clearecd individually.
080 - Planning
Prior To Building Permit Issuance
Map - FEE BALANCE (with MOU included)Status
Prior to issuance of residential building permits, the Planning Department shall determine if deposit based fees are in a negative balance and the Per-Unit Sports Park Contribution was assessed and paid per the MOU for Public Parks Implementation Agreement for Specific Plan No. 293 as Amended through Amendment No. 5 and Substantial Conformance No. 7. The property owners shall pay the applicable Per-Unit Sports Park Contribution for each housing unit in their respective Tract as shown on Exhibit A of the MOU or the number of lots that are recorded within phased maps, subsequent maps, revised or amended maps, prior to the issuance of the building permit for each housing unit for which the applicable Sports Park Contribution has been paid. The Per-Unit Sports Park Contribution fee for each of the property owners is $7,495.78. (With CPI Adjustments). Any outstanding fees shall be paid by the applicant/developer. (This Condition has been modified based upon Board approval of a Public Parks Implementation Agreement for SP293, as amended through Amd. No. 5 and Sub. Conf. No 7, on July 7, 2020.)
080 - Planning
Prior To Building Permit Issuance
MAP - FINAL SITE PLANStatus
A plot plan application shall be submitted to the County Planning Department pursuant to Section 18.30.a.(1) of County Ordinance No. 348 (Plot Plans not subject to the California Environmental Quality Act and not subject to review by any governmental agency other than the Planning Department), along with the current fee. Subdivision development shall conform to the approved plot plan and shall conform to the Countywide Design and Landscape Guidelines. The plot plan shall be approved by the Planning Director prior to issuance of building permits for lots included within that plot plan. The plot plan shall contain the following elements: 1. A final site plan (40' scale precise grading plan) showing all lots, building footprints, setbacks, mechanical equipment and model assignments on individual lots. 2. Each model floor plan and elevations (all sides). 3. Six (6) sets of photographic or color laser prints (8" x 10") of the sample board and colored elevations shall be submitted for permanent filing and agency distribution after the Planning Department has reviewed and approved the sample board and colored elevations in accordance with the approved Design Manual and other applicable standards. All writing must be legible. Six (6) matrix sheets showing structure colors and texture schemes shall be submitted. 4. At a minimum there should be three different floor plans for tract maps with 50 or less units. Reverse floor plans are not included as different floor plan. For tract maps with from 51 to 99 units, there shall be at least four different floor plans. Tract maps with 100 units or more shall provide five different floor plans and an additional floor plan for every 100 dwelling units above 100 units. For development projects that are to constructed in phases, a phasing plan shall be submitted to assure that the requirements for the number of floor plans is being met. 5. Homes and garages shall be placed at varying distances from the street and have varying entry locations. Front yard setbacks shall average 20 feet and may be varied by up to 25%, in increments of any size. The minimum front yard setback shall not be less than 15 feet. 6. The colors and materials on adjacent residential structures should be varied to establish a separate identity for the dwellings. A variety of colors and textures of building materials is encouraged, while maintaining overall design continuity in the neighborhood. Color sample boards shall be submitted as a part of the application and review process. 7. All new residences with garages shall be provided with roll-up (i.e. on tracks) garage doors (either sectional wood or steel). At least 25% of the garage doors in any project should have windows. NOTE: The requirements of this plot plan may be incorporated with any minor plot plan required by this subdivision's conditions of approval. However, this FINAL SITE DEVELOPENT plot plan conditon of approval shall be cleared individually.
080 - Planning
Prior To Building Permit Issuance
MAP - FRONT YARD LANDSCAPINGStatus
All front yards shall be provided with landscaping and automatic irrigation, as defined by County Ordinance No. 348.
080 - Planning
Prior To Building Permit Issuance
MAP - LANDSCAPE PLOT PLANStatus
The land divider/permit holder shall file seven (7) sets of a Landscaping and Irrigation Plan to the County Planning Department for review and approval. Said plan shall be submitted to the Department in the form of a plot plan application pursuant to County Ordinance No. 348, Section 18.30.a.(1) (Plot Plans not subject to the California Environmental Quality Act and not subject to review by any governmental agency other than the Planning Department), along with the current fee. The plan shall be in compliance with Section 18.12, Sections 19.300 through 19.304., and the TENTATIVE MAP conditions of approval. When the proposal is located within the [Valley-Wide Recreation and Park District][Jurupa Conmmunity Services District] or a [County Service Area (CSA)], prior to landscape plan submittal to the Planning Department, the developer/permittee shall show evidence to the Planning Department that the Valleywide Park & Recreation District has approved said plans. The plan shall show all common open space areas. The plan shall address all areas and conditions of the tract requiring landscaping and irrigation to be installed including, but not limited to, (slope planting, common area and/or park landscaping, and individual front yard landscaping). Emphasis shall be placed on using plant species that are drought tolerant and low water using. The plans shall provide for the following: 1. Permanent automatic irrigation systems shall be installed on all landscaped areas requiring irrigation. Low water use systems are encouraged. 2. All utility service areas and enclosures shall be screened from view with landscaping and decorative barriers or baffle treatments, as approved by the Planning Department. Utilities shall be placed underground. 3. Any required landscape screening shall be designed to be opaque up to a minimum height of six (6) feet at maturity. 4. Parkways and landscaped building setbacks shall be landscaped to provide visual screening or a transition into the primary use area of the site. Landscape elements shall include earth berming, ground cover, shrubs, and specimen trees in conjunction with meandering sidewalks, benches, and other pedestrian amenities where appropriate as approved by the Planning Department. 5. Landscaping plans shall incorporate the use of specimen accent trees at key visual focal points within the project. 6. Landscaping plans shall incorporate native and drought tolerant plants where appropriate. 7. All specimen trees and significant rock outcroppings on the subject property intended for retention shall be shown on the project's grading plans. Replacement trees for those to be removed shall also be shown. 8. All trees shall be minimum double-staked. Weaker and/or slow-growing trees shall be steel-staked. 9. Multi-programmable irrigation controllers which have enough programs to break up all irrigation stations into hydro zones shall be used. If practical and feasible, rain shutoff devices shall be employed to prevent irrigation after significant precipitation. Irrigation systems shall be designed so areas which have different water use requirements are not mixed on the same station (hydro zones). Assistance in implementing a schedule based on plant water needs is available from CIMIS or Mobile Lab. The use of drip irrigation should be considered for all planter areas that have a shrub density that will cause excessive spray interference of an overhead irrigation system. Use flow reducers to mitigate broken heads next to sidewalks, streets, and driveways. (BMP S2) 10. Plants with similar water requirements shall be grouped together in order to reduce excessive irrigation runoff and promote surface filtration, where possible. (BMP S3) NOTES: The Landscape plot plan my include the requirements of any other minor plot plan required by the subdivision conditions of approval. However, minor plot plan conditions of approval shall be cleared individually. Landscaping plans for areas that are totally within the road right-of-way shall be submitted to the Transportation Department ONLY.
080 - Planning
Prior To Building Permit Issuance
MAP - LANDSCAPING SECURITIESStatus
Performance securities, in amounts to be determined by the Director of Building and Safety to guarantee the installation of plantings, irrigation system, walls and/or fences, in accordance with the approved plan, shall be filed with the Department of Building and Safety. Securities may require review by County Counsel and other staff. Permit holder is encouraged to allow adequate time to ensure that securities are in place. The performance security may be released one year after structural final, inspection report, and the One-Year Post Establishment report confirms that the planting and irrigation components have been adequately installed and maintained. A cash security shall be required when the estimated cost is $2,500.00 or less. EOT1
080 - Planning
Prior To Building Permit Issuance
MAP - MODEL HOME COMPLEXStatus
A plot plan application shall be submitted to the County Planning Department pursuant to Section 18.30.a.(1) of County Ordinance No. 348 (Plot Plans not subject to the California Environmental Quality Act and not subject to review by any governmental agency other than the Planning Department), along with the current fee. The Model Home Complex plot plan shall contain the following elements: 1. An engineer's scaled plan showing the model home lots, lot numbers, tract number, and north arrow. 2. Show front, side and rear yard setbacks. 3. Provide two dementioned off street parking spaces per model and one parking space for office use. The plan must have one accessible parking space. 4. Show detailed fencing plan including height and location. 5. Show typical model tour sign locations and elevation. 6. Six (6) sets of photographic or color laser prints (8" X 10") of the sample board and colored elevations shall be submitted for permaanent filing and agency distribution after the Plannning Department has reviewed and approved the sample board and colored elevations in accordance with the approved Design Manual and other applicable standards. All writing must be legible. Six (6) matrix sheets showing structure colors and texture schemes shall be submitted. 7. Provide a Model Home Complex landscape and irrigation plan. NOTES: The Model Home Complex plot plan shall not be approved without Final Site Development Plan approval, or concurrent approval of both. See the Planning Department Model Home Complex application for detailed requirements. The requirements of this plot plan may be incorporated with any minor plot plan required by the subdivision's conditions of approval. However, this MODEL HOME COMPLEX condition of approval shall be cleared individually.
080 - Planning
Prior To Building Permit Issuance
MAP - PARKING/LANDSCAPING PLANStatus
Prior to issuance of building permits, seven (7) copies of a Shading, Parking, Landscaping, and Irrigation Plan shall be submitted to and approved by the Planning Department. The location, number, genus, species, and container size of plants shall be shown. Plans shall meet all requirements of the Riverside County Guide to California Friendly Landscaping, and Ordinance No. 348, Sections 18.12, and 19.300 through 19.304 and as specified herein, and Ordinance No. 859 (as adopted and any amendments thereto) provided that said ordinance has been amended to address residential tracts. The irrigation plan shall include a smart controller which is capable of adjusting watering schedule based on weather data. In addition, the plan will incorporate the use of in-line check valves, or sprinkler heads containing check valves to prohibit low head drainage. EOT1
080 - Planning
Prior To Building Permit Issuance
MAP - PLANNING AREA PARKStatus
Prior to the issuance of any building permits within Planning Area 31, 33, 34, 38a, 38b, 40, 43, 44, 45a, 45b, 46, 47a or 47b detailed park plans shall be submitted to and approved by the Planning Department and the Valley-Wide Recreation and Park District or other entity as set forth in condition of Approval No. 3.11 for the park sites identified as Planning Areas 32 and 37. The detailed park plans shall provide for active reacreational facilities and uses, and shall conform with the design criteria described in the specific plan document for Planning areas 32 and 37 and with the requirements of the Valley-Wide Recreation and Park District or other entity as set forth in Condition of Approval No. 3.11. The detailed park plans shall include landscape and irrigation plans and documentation evidencing a permanent maintenance mecnanism for the park and its facilities. Prior to the issuance of the 250th occupancy permit anywhere within the area defined as Planning Areas 31, 33, 34, 35, 38a, 38b, 40,43,44,45a, 45b, 46, 47a, and 47b, the park designated as Planning Area 37 shall be constructed in accordance with approved park plans and fully operable. Prior to the issuance of the 500th occupancy permit anywhere within the area described as Planning Areas 31, 33, 34, 35, 38a, 38b, 40, 43, 44, 45a, 45b, 46, 47a, and 47b, the park designated a Planning Area 32 shall be constructed in accordance with approved park plans and fully operable. (Amended by the Planning Commission on 10/25/95.)
080 - Planning
Prior To Building Permit Issuance
MAP - PLANNING CLEARANCE PRIORStatus
Prior to issuance of a building permit for the construction of any use contemplated by this approval, the applicant shall first obtain clearance from the Riverside County Planning Department that all pertinent conditions of approval have been satisfied with the specific plan for the phase of development in question. This condition implements 30.PLANNING.27 of the Specific Plan.
080 - Planning
Prior To Building Permit Issuance
MAP - ROOF MOUNTED EQUIPMENTStatus
Roof-mounted mechanical equipment shall not be permitted within the subdivision, however, solar equipment or any other energy saving devices shall be permitted with County Planning Department approval.
080 - Planning
Prior To Building Permit Issuance
MAP - SCHOOL MITIGATIONStatus
Impacts to the Hemet Unified School District shall be mitigated in accordance with California State law. This condition implements 30.PLANNING.33 of the Specific Plan.
080 - Planning
Prior To Building Permit Issuance
MAP - SUBMIT BUILDING PLANSStatus
The land divider/permit holder shall cause building plans to be submitted to the TLMA - Land Use Division for review by the County Department of Building and Safety - Plan Check Division. Said plans shall be in conformance with the TENTATIVE MAP.
080 - Planning
Prior To Building Permit Issuance
MAP - UNDERGROUND UTILITIESStatus
All utility extensions within a lot shall be placed underground.
080 - Planning
Prior To Building Permit Issuance
MAP - Walls/Fencing PlansStatus
The land divider/permit holder shall file seven (7) sets of a Wall/Fencing Plan to the County Planning Department for review and approval. Said plan shall be submitted to the Department in the form of a plot plan application pursuant to County Ordinance No. 348, Section 18.30.a.(1) (Plot Plans not subject to the California Environmental Quality Act and not subject to review by any governmental agency other than the Planning Department), along with the current fee. The plan shall be in compliance with Section 18.12, and the TENTATIVE MAP conditions of approval. A. The plan shall show all project fencing including, but not limited to, perimeter fencing, side and rear yard fencing, and open space or park fencing. A typical frontal view of all fences shall be shown on the fencing plan. B. All utility service areas and enclosures shall be screened from view with landscaping or decorative barriers or baffle treatments, as approved by the Planning Department. C. All wood fencing shall be treated with heavy oil stain to match the natural shade to prevent bleaching from irrigation spray. D. Front yard return walls shall be constructed of masonry (slump stone or material of similar appearance, maintenance, and structural durability) and shall be a minimum of five feet in height. E. Side yard gates are required on one side of front yard, and shall be constructed of wrought iron, wood, vinyl or tubular steel. Side and rear yard fencing shall be masonry, slump stone or other material of similar appearance, maintenance, and structural durability. Chain link fencing is not permitted. All construction must be of good quality and sufficient durability with an approved stain and/or sealant to minimize water staining. (Applicants shall provide specifications that shall be approved by the Planning Department). F. All new residences constructed on lots of less than 20,000 square feet shall include rear and side yard fencing constructed of masonry block that is a minimum of five (5) feet in height. The maximum height of walls or fencing shall be six (6) feet in height. In the desert areas, block walls are discouraged on the perimeter in favor of increased setbacks with extensive drought tolerant landscaping, berms and fencing such as split rails. G. Except for the desert areas, all lots having rear and/or side yards facing local streets or otherwise open to public view shall have fences or walls constructed of decorative block, H. Corner lots shall be constructed with wrap-around decorative block wall returns. (Note: exceptions for the desert area discussed above.) I. Side yard gates are required on one side of the home and shall be constructed of powder-coated wrought iron or tubular steel. J. Wrought iron or tubular steel fence sections may be included within tracts where view opportunities and/or terrain warrant its use. Where privacy of views is not an issue, tubular steel or wrought iron sections should be constructed in perimeter walls in order to take advantage of casual view opportunities.
080 - Planning
Prior To Building Permit Issuance
Quimby deffered from prior to map recStatus
Differed at the request of applicant and Valleywide, from prior to map recordation, to prior to first building permit: The land divider shall submit to the County Planning Department - Development Review Division a duly and completely executed agreement with the Valleywide Recreation and Parks District which demonstrates to the satisfaction of the County that the land divider has provided for the payment of parks and recreation fees and/or dedication of land for the TENTATIVE MAP in accordance with Section 10.35 of County Ordinance No. 460. (See letter from Valleywide attached to Tract in PLUS.)
080 - Planning-EPD
Prior To Building Permit Issuance
EPD-EPD - MBTA REPORTStatus
Prior to the issuance of any building permits, the biologist who carried out the MBTA survey(s) shall submit a written report for review to EPD. At a minimum the report shall provide survey results and describe any mitigation measures that may have been employed to avoid take of any MBTA covered species.
080 - Transportation
Prior To Building Permit Issuance
EOT4 -WQMP AND MAINTENANCEStatus
The project shall begin constructing and installing the BMP facilities described in the approved Final WQMP. The project shall be responsible for performing all activities described in the WQMP and that copies of the approved Final WQMP are available for the future owners/occupants. A maintenance plan and signed maintenance agreement shall be submitted to the Transportation Department for review and approval prior to issuance of occupancy permits. A maintenance organization will be established with a funding source for the permanent maintenance. The maintenance plan shall require that all BMP facilities are inspected, if required, cleaned no later than October 15 each year. (This Extension of Time condition may be considered "Met" if it duplicates another similar condition issued by this department)
080 - Transportation
Prior To Building Permit Issuance
MAP - GARAGE DOORSStatus
Garage door setbacks for all residential zones shall be 24 feet for a conventional door or 20 feet for a roll-up door, measured from the back of the sidewalk to the face of garage door or the face of the curb if no sidewalk is required, or 20 feet from the street right-of-way, whichever setback is greater.
080 - Transportation
Prior To Building Permit Issuance
MAP - R & B B DStatus
Prior to the recordation of the final map, or any phase thereof, the project proponent shall pay fees in accordance with Zone E of the Menifee Valley Road and Bridge Benefit District. Should the project proponent choose to defer the time of payment, a written request shall be submitted to the County, deferring said payment to the time of issuance of a building permit. Fees which are deferred shall be based upon the fee schedule in effect at the time of issuance of the permit.
080 - Transportation
Prior To Building Permit Issuance
MAP - RICE ROAD BRIDGEStatus
The following condition of approval has been deferred from a portion of 50.TRANS.003, MAP - DEDICATIONS. Rice Road shall be improved within the dedicated right-of-way in accordance with Countywide Design Standard, Exhibit 'H'. (32'/50') *NOTE* This will require a bridge 32'/50' as determined by the Transportation Department. (modified)
080 - Transportation
Prior To Building Permit Issuance
USE - TUMF CREDIT AGREEMENTStatus
If the applicant/developer is constructing a "TUMF" facility as a condition of approval for this project and will be seeking "TUMF" credits and/or reimbursements for the "TUMF" improvements built with this project, the applicant shall enter into a "TUMF Improvement and Credit Agreement" with the Transportation Department prior to the first building permit issuance as directed by the Director of Transportation. Please contact (951) 955-6800 for additional information.
090 - BS-Grade
Prior to Building Final Inspection
Grade-EOT3- BMP GPS COORDINATESStatus
Prior to final building inspection, the applicant/owner shall provide the Department of Building Safety with GPS coordinates for the location of the project - specific WQMP treatment control BMPs.
090 - BS-Grade
Prior to Building Final Inspection
Grade-EOT3- REQ'D GRDG INSP'SStatus
The developer / applicant shall be responsible for obtaining the following inspections required by Ordinance 457. 1.Precise grade inspection. a.Precise Grade Inspection can include but is not limited to the following: 1.Installation of slope planting and permanent irrigation on required slopes. 2.Completion of drainage swales, berms and required drainage away from foundation. b.Inspection of completed onsite drainage facilities c.Inspection of the WQMP treatment control BMPs
090 - BS-Grade
Prior to Building Final Inspection
Grade-EOT3- WQMP ANNUAL INSP FEEStatus
Prior to final building inspection, the applicant shall make payment to the Building and Safety Department for the Water Quality Management Plan (WQMP) Annual Inspection.
090 - BS-Grade
Prior to Building Final Inspection
Grade-EOT3- WQMP BMP CERT REQ'DStatus
Prior to final building inspection, the applicant/owner shall submit a "Wet Signed" copy of the Water Quality Management Plan (WQMP) Certification from a Registered Civil Engineer certifying that the project - specific WQMP treatment control BMPs have been installed in accordance with the approved WQMP.
090 - BS-Grade
Prior to Building Final Inspection
Grade-EOT3- WQMP BMP INSPECTIONStatus
Prior to final building inspection, the applicant shall obtain inspection of all treatment control BMPs and/or clearance from the Building and Safety Department. All structural BMPs described in the project - specific WQMP and indicated on the approved grading plan shall be constructed and installed in conformance with the approved plans and specifications. The Building and Safety Department must inspect and approve the completed WQMP treatment control BMPs for your project before a building final can be obtained.
090 - BS-Grade
Prior to Building Final Inspection
Grade-EOT3- WQMP BMP REGISTRATIONStatus
Prior to final building inspection, the applicant/owner shall register the project - specific WQMP treatment control BMPs with the Department of Building Safety Business Registration Division. Any person or entity that owns or operates a facility conditioned to install WQMP treatment control BMPs shall register such facility for annual inspections.
090 - BS-Grade
Prior to Building Final Inspection
Grade-EOT4 - WQMP REQUIREDStatus
Prior to final building inspection, the applicant shall comply with the following: 1. Obtain inspection of all treatment control BMPs and/or clearance from the Building and Safety Department. All structural BMPs described in the project - specific WQMP and indicated on the approved grading plan shall be constructed and installed in conformance with the approved plans and specifications. 2. The applicant/owner shall submit a "Wet Signed" copy of the Water Quality Management Plan (WQMP) Certification from a Registered Civil Engineer certifying that the project - specific WQMP treatment control BMPs have been installed in accordance with the approved WQMP. 3. The applicant/owner shall provide the Department of Building Safety with GPS coordinates for the location of the project - specific WQMP treatment control BMPs. 4. The applicant/owner shall register the project - specific WQMP treatment control BMPs with the Department of Building Safety Business Registration Division. Any person or entity that owns or operates a commercial and/or industrial facility shall register such facility for annual inspections. 5. The applicant shall make payment to the Building and Safety Department for the Water Quality Management Plan (WQMP) Annual Inspection. (This Extension of Time condition may be considered "Met" if it duplicates another similar condition issued by this department)
090 - BS-Grade
Prior to Building Final Inspection
Grade-MAP-G4.1E-CL 4:1 OR STEEPERStatus
Plant and irrigate all manufactured slopes steeper than a 4:1 (horizontal to vertical) ratio and 3 feet or greater in vertical height with grass or ground cover; slopes 15 feet or greater in vertical height shall be planted with additional shrubs or trees as approved by the Building & Safety Department's Erosion Control Specialist.
090 - BS-Grade
Prior to Building Final Inspection
Grade-MAP-G4.2 1/2"/FT/3FT MINStatus
Finish grade shall be sloped to provide proper drainage away from all exterior foundation walls. The slope shall be not less than one-half inch per foot for a distance of not less than 3 feet from any point of exterior foundation. Drainage swales shall not be less than 1 1/2 inches deeper than the adjacent finish grade at the foundation.
090 - BS-Plan Check
Prior to Building Final Inspection
Plan Check-BP - MSHCP FEE/ORDS 810 & 875Status
Prior to the final inspection, applicants are required to pay the Riverside County Multiple Species Habitat Conservation Plan fees required by either Ordinance 810, Western MSHCP or Ordinance 875, Coachella Valley MSHCP.
090 - Flood
Prior to Building Final Inspection
MAP BMP - EDUCATIONStatus
The developer shall distribute environmental awareness education materials on general good housekeeping practices that contribute to protection of stormwater quality to all initial residents. The developer may obtain NPDES Public Educational Program materials from the District's website: www.rcwatershed.org/about/materials-library. The developer must provide to the District's Plan Check Department a notarized affidavit stating that the distribution of educational materials to the tenants is assured prior to the issuance of occupancy permits. If conditioned for a Water Quality Management Report (WQMP), a copy of the notarized affidavit must be placed in the report. The District MUST also receive the original notarized affidavit with the plan check submittal in order to clear the appropriate condition. Placing a copy of the affidavit without submitting the original will not guarantee clearance of the condition.
090 - Flood
Prior to Building Final Inspection
MAP OBTAIN LOMRStatus
A Letter of Map Revision shall be obtained from FEMA for all lots impacted by a FEMA floodplain.
090 - Planning
Prior to Building Final Inspection
MAP - BLOCK WALL ANTIGRAFFITIStatus
The land divider/permit holder shall construct a five (5) foot high decorative block wall along Olive Road, a six (6) foot high decorative block wall along Rice Road, and a eight (8) foot high decorative block wall along Newport Road. The required wall shall be subject to the approval of the County Department of Building and Safety. An anti-graffiti coating shall be provided on all block walls, and written verification from the developer shall be provided to both the TLMA - Land Use Division, and the Development Review Division.
090 - Planning
Prior to Building Final Inspection
MAP - COMPLY W/ LNDSCP/IRRIGStatus
All required landscape planting and irrigation shall have been installed in accordance with approved Landscaping, Irrigation, and Shading Plans, and the Riverside County Guide to California Landscaping, and Ordinance No. 859 (as adopted and any amendments thereto) provided that said ordinance has been amended to address residential tracts. All landscape and irrigation components shall be in a condition acceptable to the Planning Department through the implementation of the Department's Milestone 90 condition entitled "MAP - LNDSCP/IRRIG INSTALL INS." The plants shall be healthy and free of weeds, disease or pests. The irrigation system shall be properly constructed and determined to be in good working order. EOT1
090 - Planning
Prior to Building Final Inspection
MAP - CONCRETE DRIVEWAYSStatus
The land divider/permit holder shall cause all driveways to be constructed of cement concrete.
090 - Planning
Prior to Building Final Inspection
MAP - FENCING COMPLIANCEStatus
Fencing shall be provided throughout the subdivision in accordance with the approved final site development plans.
090 - Planning
Prior to Building Final Inspection
MAP - LANDSCAPING COMPLIANCEStatus
The land divider/permit holder's landscape architect or other state licensed party responsible for preparing the landscape and irrigation plans shall provide a Compliance Letter to the County Planning Department and the County Department of Building and Safety stating that the landscape and irrigation system has been installed in compliance with the approved landscaping and irrigation plans. The Compliance letter shall be submitted at least three (3) working days prior to final inspection of the structure or issuance of occupancy permit, whichever comes first.
090 - Planning
Prior to Building Final Inspection
MAP - LNDSCP/IRRIG INSTALL INSStatus
The permit holder's landscape architect responsible for preparing the Landscaping and Irrigation Plans shall arrange for an Installation Inspection with the Planning Department at least fifteen (15) working days prior to final Inspection of the structure or issuance of occupancy permit, whichever occurs first. Upon successful completion of the Installation Inspection and compliance with the Planning Department's Milestone 80 conditions entitled "MAP-LANDSCAPING SECURITIES and MAP- LNDSCPE INSPECTION DEPOS," both the County Planning Department's Landscape Inspector and the permit holder's landscape architect shall execute a Certificate of Completion that shall be submitted to the Planning Department and the Department of Building and Safety. Costs associated with the Installation Inspection will be charged to the respective building permit. EOT1
090 - Planning
Prior to Building Final Inspection
MAP - MITIGATION MONITORINGStatus
The land divider/permit holder shall prepare and submit a written report to the Riverside County Planning Department demonstrating compliance with all these conditions of approval and mitigation measures of this permit and Environmental Assessment No. 39236. The Planning Director may require inspection or other monitoring to ensure such compliance.
090 - Planning
Prior to Building Final Inspection
MAP - QUIMBY FEES (2)Status
The land divider/permit holder shall present certification to the Riverside County Planning Department that payment of parks and recreation fees and/or dedication of land for park use in accordance with Section 10.35 of County Ordinance No. 460 has taken place. Said certification shall be obtained from the Valleywide Park & Recreation District.
090 - Planning
Prior to Building Final Inspection
MAP - SKR FEE CONDITIONStatus
Prior to the issuance of a certificate of occupancy, or upon building permit final inspection, whichever comes first, the land divider/permit holder shall comply with the provisions of Riverside County Ordinance No. 663, which generally requires the payment of the appropriate fee set forth in that ordinance. The amount of the fee required to be paid may vary, depending upon a variety of factors, including the type of development application submitted and the applicability of any fee reduction or exemption provisions contained in Riverside County Ordinance No. 663. Said fee shall be calculated on the approved development project which is anticipated to be 55.59 acres (gross) in accordance with TENTATIVE MAP. If the development is subsequently revised, this acreage amount may be modified in order to reflect the revised development project acreage amount. In the event Riverside County Ordinance No. 663 is rescinded, this condition will no longer be applicable. However, should Riverside County Ordinance No. 663 be rescinded and superseded by a subsequent mitigation fee ordinance, payment of the appropriate fee set forth in that ordinance shall be required.
090 - Planning
Prior to Building Final Inspection
MAP - SPECIMEN TREES REQUIREDStatus
Landscaping plans shall incorporate the use of specimen (24" box or greater) canopy trees long streets and within the parking areas. All trees and shrubs shall be drawn to reflect the average specimen size at 15 years of age. All trees shall be double-staked and secured with non-wire ties. EOT1
090 - Planning
Prior to Building Final Inspection
MAP- ROLL-UP GARAGE DOORSStatus
All residences shall have automatic roll-up garage doors.
090 - Planning
Prior to Building Final Inspection
DEVELOPMENT IMPACT FEES (Ord. 659)Status
The project shall comply with County Ordinance.
090 - Planning
Prior to Building Final Inspection
OPEN SPACE FEES (Ord. 810)Status
The project shall comply with County Ordinance.
090 - Transportation
Prior to Building Final Inspection
EOT4 - WQMP COMP AND BNS REGStatus
Prior to Building Final Inspection, the applicant will be required to hand out educational materials regarding water quality, provide a engineered WQMP certification, inspection of BMPs, GPS location of BMPs, and ensure that the requirements for inspection and cleaning the BMPs are established. Additionally, the applicant will be required to register BMPs with the Transportation Department's Business Registration Division. (This Extension of Time condition may be considered "Met" if it duplicates another similar condition issued by this department)
090 - Transportation
Prior to Building Final Inspection
MAP - 80% COMPLETIONStatus
Occupancy releases will not be issued to Building and Safety for any lot exceeding 80% of the total recorded residential lots within any map or phase of map prior to completion of the following improvements: a) Primary and Alternate (secondary) access roads shall be completed and paved to finish grade according to the limits indicated in the improvement plans and as noted elsewhere in these conditions. b) Interior roads shall be completed and paved to finish grade according to the limits indicated in the improvement plans and as noted elsewhere in these conditions. All curbs, gutters, sidewalks and driveway approaches shall be installed. c) Storm drains and flood control facilities shall be completed according to the improvement plans and as noted elsewhere in these conditions. Written confirmation of acceptance for use by the Flood Control District, if applicable, is required. d) Water system, including fire hydrants, shall be installed and operational, according to the improvement plans and as noted elsewhere in these conditions. All water valves shall be raised to pavement finished grade. Written confirmation of acceptance from water purveyor is required. e) Sewer system shall be installed and operational, according to the improvement plans and as noted elsewhere in these conditions. All sewer manholes shall be raised to pavement finished grade. Written confirmation of acceptance from sewer purveyor is required. f) Landscaping and irrigation, water and electrical systems shall be installed and operational in accordance with County Ordinance 461.
090 - Transportation
Prior to Building Final Inspection
MAP - GRAFFITI ABATEMENT EOT1Status
Prior to issuance of an occupancy permit the project proponent shall complete annexation to Landscaping and Lighting Maintenance District NO. 89-1-Consolidated for graffiti abatement of walls and other permanent structures along County maintained road rights-of-way.
090 - Transportation
Prior to Building Final Inspection
MAP - LANDSCAPING EOT1Status
Prior to issuance of an occupancy permit, the project proponent shall complete annexation to Landscaping and Lighting Maintenance District NO. 89-1-Consolidated , County Service Area and/or Assessment District as approved by the Transportation Department for continuous landscape maintenance within for continuous landscape maintenance within public road rights-of-way, in accordance with Ordinance 461.
090 - Transportation
Prior to Building Final Inspection
MAP - R & B B DStatus
DEFERRED FR 080 TRANS MAP-R&BBD Prior to the recordation of the final map, or any phasethereof, the project proponent shall pay fees in accordance with Zone E of the Menifee Valley Road and Bridge Benefit District. Should the project proponent choose to defer the time of payment, a written request shall be submitted to the County, deferring said payment to the time of issuance of a building permit. Fees which are deferred shall be based upon the fee schedule in effect at the time of issuance of the permit.
090 - Transportation
Prior to Building Final Inspection
MAP - STREET LIGHTS INSTALLStatus
Install street lights along the streets associated with development in accordance with the approved street lighting plan and standards of County Ordinance 460 and 461. For projects within Imperial Irrigation District (IID) use (IID's) pole standard. Street light annexation into L&LMD or similar mechanism as approved by the Transportation Department shall be completed.
090 - Transportation
Prior to Building Final Inspection
MAP - STREET SWEEPINGStatus
Street sweeping annexation or inclusion into CSA or similar mechanism as approved by the Transportation Department shall be completed.
090 - Transportation
Prior to Building Final Inspection
MAP - TRAFFIC SIGNAL 2 EOT1Status
Prior to issuance of an occupancy permit the project proponent shall complete annexation to Landscaping and Lighting Maintenance District No. 89-1-Consolidated for maintenance of traffic signals within public road rights-of-way for the required traffic signal(s).
090 - Transportation
Prior to Building Final Inspection
MAP - TS/INSTALLATIONStatus
The project proponent shall be responsible for the construction and installation of traffic signals at the following location: - Rice Road/Newport Road with fee credit eligibility or as approved by the Transportation Department. The project proponent shall contact the Transportation Department and enter into an agreement for signal mitigation fee credit or reimbursement prior to start of construction of the signal. All work shall be preapproved by and shall comply with the requirements of the Transportation Department and the public contracts code in order to be eligibility for fee credit or reimbursement.
090 - Transportation
Prior to Building Final Inspection
MAP - UTILITY INSTALL EOT1Status
Electrical power, telephone, communication, street lighting, and cable television lines shall be placed underground in accordance with ordinance 460 and 461, or as approved by the Transportation Department. This also applies to existing overhead lines which are 33.6 kilovolts or below along the project frontage and between the nearest poles offsite in each direction of the project site. A certificate should be obtained from the pertinent utility company and submitted to the Department of Transportation as proof of completion.
090 - Transportation
Prior to Building Final Inspection
MAP - WRCOG TUMFStatus
Prior to the issuance of an occupancy permit, the project proponent shall pay the Transportation Uniform Mitigation Fee (TUMF) in accordance with the fee schedule in effect at the time of issuance, pursuant to Ordinance No. 824.

Conditions of Approval for Another Case



Go Back To Previous Page