ONLINE SERVICES

CONDITIONS OF APPROVAL FOR pp24300

Online Services

Results for pp24300 as of 6/3/2026 7:29:05 PM

015 - Fire
UNKNOWN
USE-#20-STANDARD FIRE HYDRANTStatus
A Standard fire hydrant (6"x4"x 2-2 1/2") shall be located at the driveway entrance.
015 - Fire
UNKNOWN
USE-#23-MIN REQ FIRE FLOWStatus
Minimum required fire flow shall be 1000 GPM for a 2 hour duration at 20 PSI residual operating pressure, which must be available before any combustible material is placed on the job site.
015 - Fire
UNKNOWN
USE-#50-BLUE DOT REFLECTORStatus
Blue retroreflective pavement markers shall be mounted on private street, public streets and driveways to indicate location of fire hydrants. Prior to installation, placement of markers must be approved by the Riverside County Fire Department.
015 - General
UNKNOWN
PPA - NO COMMERCIAL USEStatus
No commercial use allowed on this property, unless the applicant applies for Plot Plan/Conditional Use Permit for commercial use.
015 - General
UNKNOWN
PPA - NO COMMERCIAL VEHICLESStatus
At no time can commercial vehicles be store on the property for any length of time.
015 - Planning
UNKNOWN
GEN - IF HUMAN REMAINS FOUNDStatus
The developer/permit holder or any successor in interest shall comply with the following codes for the life of this project: If human remains are encountered, State Health and Safety Code Section 7050.5 states that no further disturbance shall occur until the County Coroner has made the necessary findings as to origin. Further, pursuant to Public Resources Code Section 5097.98 (b), remains shall be left in place and free from disturbance until a final decision as to the treatment and their disposition has been made. If the Riverside County Coroner determines the remains to be Native American, the Native American Heritage Commission shall be contacted within the period specified by law. Subsequently, the Native American Heritage Commission shall identify the "Most Likely Descendant." The Most Likely Descendant shall then make recommendations and engage in consultation with the County and the property owner concerning the treatment of the remains as provided in Public Resources Code Section 5097.98. Human remains from other ethnic/cultural groups with recognized historical associations to the project area shall also be subject to consultation between appropriate representatives from that group and the County Planning /Director.
015 - Planning
UNKNOWN
GEN - INADVERTANT ARCHAEO FINDStatus
The developer/permit holder or any successor in interest shall comply with the following for the life of this project: If during ground disturbance activities, cultural resources are discovered that were not assessed by the archaeological reports and/or environmental assessment conducted prior to project approval, the following procedures shall be followed. A cultural resources site is defined, for this condition, as being three or more artifacts in close association with each other, but may include fewer artifacts if the area of the find is determined to be of significance due to it sacred or cultural importance. 1.All ground disturbance activities within 100 feet of the discovered cultural resource shall be halted until a meeting is convened between the developer, the project archaeologist, the Native American tribal representative (or other appropriate ethic/cultural group representative), and the Planning Director to discuss the significance of the find. 2.At the meeting, the significance of the discoveries shall be discussed and fter consultation with the Native American tribal (or other appropriate ethnic/cultural group representative) and the archaeologist, a decision is made, with the concurrence of the Planning Director, as to the appropriate mitigation (documentation, recovery, avoidance, etc) for the cultural resource. 3.Further ground disturbance shall not resume within the area of the discovery until an agreement has been reached by all parties as to the appropriate preservation or mitigation measures.
015 - Planning
UNKNOWN
PPA - ACSRY STRC NO HBTBL AREAStatus
No habitable area has been approved with this approval. The addition of habitable area will require additional approvals.
015 - Planning
UNKNOWN
PPA - LANDUSE APPROVAL ONLYStatus
The applicant or the applicant's successor in interest is notified through this condition that the approval granted on Plot Plan No. 24300 is for land use approval only, and has only met the requirements of Ordinance 348. Any requirements deemed necessary by another department or agency of Riverside County on a subsequent building permit are valid and may cause this approval by the Riverside County Planning Department as it stands to be rendered null and void or require significant revision. It is incumbent upon the applicant to research the acceptability of this proposal to all responsible departments and agencies prior to the acceptance of this approval. Responsible agencies include, but are not limited to the Fire Department, Environmental Health Department, the local Flood Control District, Building and Safety Department, Transportation Department, the Environmental Programs Department, the County Geologist, or the Transportation Land Management Agency.
015 - Planning
UNKNOWN
PPA - NO HOME OCCUPATIONSStatus
No home occupations are permitted in an accessory structure or guest home. From section 21.36 of Ordinance 348: Home Occupations: Home occupations means those uses that are customarily conducted in a residence, provided such uses must be incidental and secondary to the principal use of a dwelling as a residence. The following criteria shall apply to any home occupation: a. Except for large family day care homes which may require two assistants and small family day care homes which may require one assistant to be present in addition to the licensee or provider, no person other than a resident of the dwelling shall be employed on the premises in the conduct of a home occupation. b. A home occupation shall be conducted entirely within the dwelling and shall be incidental and secondary to the use of the dwelling as a residence. c. A home occupation shall not be conducted in an accessory structure and there shall be no storage of equipment or supplies in an accessory structure or outside building. d. The residential character of the exterior and interior of the dwelling shall not be changed. e. No vehicles or trailers except those normally incidental to residential use shall be kept on the site. f. No signs other than one unlighted identification sign, not more than two square feet in area, shall be erected on the premises.
015 - Planning
UNKNOWN
PPA - SETBACKS IN HIGH FIREStatus
Please be advised that the setbacks for structures within a County designated high fire areas have increased. It is advisable prior to the purchase of structure or prior to planning of a structure (such as hiring an architect or engineer to create plans) that the applicant should contact the Fire Department to make sure that the structure question meets those requirements. Fire Department Planning 2300 Market Street, Suite 150 Riverside, CA 92501 951-955-4777
015 - Planning
UNKNOWN
PPA - EXISTING STRUCTURE (1)Status
WITHIN SIXTY (60) DAYS OF THE EFFECTIVE DATE OF THIS PERMIT, the permittee or the permittee's successors-in- interest shall apply to the Building and Safety Department for all necessary permits, including the submission of all required documents and fees for any plan check review as determined by the Director of the Department of Building and Safety, to ensure that all existing buildings, structures and uses are in compliance with Ordinance No. 348 and Ordinance No. 457 and the conditions of approval of this permit.
015 - Planning
UNKNOWN
PPA - EXPIRATION DATE-PPStatus
This approval shall be used within two (2) years of approval date; otherwise, it shall become null and void and of no effect whatsoever. By use is meant the beginning of substantial construction comtemplated by this approval within a two (2) year period which is thereafter diligently pursued to completion or to the actual occupancy of exisiting buildings or land under the terms of the authorized use. Prior to the expiration of the two year period, the permittee may request a one (1) year extension of time request in which to use this plot plan. A maximum of three one-year extension of time requests shall be permitted. Should the time period established by any of the extension of time requests lapse, or should all three one-year extensions be obtained and no substantial construction or use of this plot plan be initiated within five (5) years of the effective date of the issuance of this plot plan, this plot plan shall become null and void.
015 - Planning-All
UNKNOWN
All-PPA - DEFINITIONSStatus
The words identified in the following list that appear in all capitals in the attached conditions of Plot Plan No. 24300 shall be henceforth defined as follows: APPROVED EXHIBIT A = Plot Plan No. 24300 , Exhibit A, Amended #1, dated December 9, 2009.
015 - Planning-All
UNKNOWN
All-PPA - HOLD HARMLESSStatus
The applicant/permittee or any successor-in-interest shall defend, indemnify, and hold harmless the County of Riverside COUNTY), its agents, officers, or employees from any claim, action, or proceeding against the COUNTY, its agents, officers, or employees to attack, set aside, void, or annul an approval of the COUNTY, its advisory agencies, appeal boards, or legislative body concerning PP24300. The COUNTY will promptly notify the applicant/ permittee of any such claim, action, or proceeding against the COUNTY and will cooperate fully in the defense. If the COUNTY fails to promptly notify the applicant/permittee of any such claim, action, or proceeding or fails to cooperate fully in the defense, the applicant/permittee shall not, thereafter, be responsible to defend, indemnify, or hold harmless the COUNTY.
015 - Planning-All
UNKNOWN
All-PPA - PROJECT DESCRIPTIONStatus
The use hereby permitted is to construct a 5,625 square foot detached metal storage building on 4.77 acres associated with the 3,517 square foot residence located at 25816 Los Randerias Road in Hemet, CA. APN: 455-120-035
080 - Fire
Prior To Building Permit Issuance
USE-#4-WATER PLANSStatus
The applicant or developer shall separately submit two copies of the water system plans to the Fire Department for review and approval. Calculated velocities shall not exceed 10 feet per second. Plans shall conform to the fire hydrant types, location and spacing, and the system shall meet the fire flow requirements. Plans shall be signed and approved by a registered civil engineer and the local water company with the following certification: "I certify that the design of the water system is in accordance with the requirements prescribed by the Riverside County Fire Department."
080 - Planning
Prior To Building Permit Issuance
PPA - CONFORM TO ELEVATIONSStatus
Elevations of all buildings and structures submitted for building plan check approval shall be in substantial conformance with the elevations shown on APPROVED EXHIBIT B, Amended #1, dated December 9, 2009.
080 - Planning
Prior To Building Permit Issuance
PPA - CONFORM TO FLOOR PLANSStatus
Floor plans shall be in substantial conformance with that shown on APPROVED EXHIBIT C, Amended #1, dated December 9, 2009.
080 - Planning
Prior To Building Permit Issuance
PPA - EXISTING STRUCTUREStatus
PRIOR TO BUILDING PERMIT ISSUANCE, the permittee or the permittee's successors-in- interest shall apply to the Building and Safety Department for all necessary permits, including the submission of all required documents and fees for any plan check review as determined by the Director of the Department of Building and Safety, to ensure that all existing buildings, structures and uses are in compliance with Ordinance No. 348 and Ordinance No. 457 and the conditions of approval of this permit. (This condition only applies when there are existing unpermitted structures on the property in addition to the proposed structure. Planner note: delete this comment)
090 - Fire
Prior to Building Final Inspection
USE-#12A-SPRINKLER SYSTEMStatus
Install a complete fire sprinkler system per NFPA 13D 2002 edition. A statement that the building(s) will be automatically fire sprinkled must be included on the title page of the building plans.Plans must be submitted to the Fire Dept. for review and approval prior to installation.
090 - Fire
Prior to Building Final Inspection
USE-#27-EXTINGUISHERSStatus
nstall portable fire extinguishers with a minimum rating of 2A-10BC and signage. Fire Extinguishers located in public areas shall be in recessed cabinets mounted 48" (inches) to center above floor level with maximum 4" projection from the wall. Contact Fire Department for proper placement of equipment prior to installation.

Conditions of Approval for Another Case